SECTION 5 – MAINTENANCE AND TROUBLESHOOTING
Inspection and service of this gate operator by a qualified technician should be performed anytime a
malfunction is observed or suspected. High cycle usage may require more frequent service checks.
5.1 Maintenance
When servicing the gate operator, always check any secondary (external) reversing devices (loops,
photo eyes, etc.) for proper operation. If external reversing devices cannot be made operable, do not
place this operator in service until the malfunction can be identified and corrected.
Always check the inherent reversing system when performing any maintenance. If the
inherent reversing system cannot be made operable, remove this operator from service until
the cause of the malfunction is identified and corrected. Keeping this operator in service
when the inherent reversing system is malfunctioning creates a hazard for persons which can
result in serious injury or death should they become entrapped in the gate.
When servicing this gate operator, always turn power OFF!!
MONTHLY
INTERVAL
MAINTENANCE SCHEDULE 3 6 12
Alarm Activate the primary (inherent) reverse system by blocking the gate
with a solid object. When the gate reverses, block the gate in the
opposite direction prior to the limit being reached. The entrapment
alarm should activate. Press the reset button to silence the alarm.
Chain Check for sagging. Tighten if necessary.
Fire Dept. Check emergency vehicle access device for proper operation.
Gate Inspect for damage. Check gate wheels, rollers and guides for
wear and grease if necessary.
Grease Wheels and guide rollers if necessary.
Loop(s) Check vehicular reverse and shadow loops for proper operation.
Primary Reverse
System Check that the gate reverses on contact with an object in both the
opening and closing cycles. Adjust reversing sensitivity if
necessary.
Release Check manual release for proper operation.
Secondary
Reverse Device Check that secondary (external) reverse device(s) stop or reverse
the gate when activated.
Sprockets Check setscrews for tightness.
Complete Complete check of gate and gate operating system.
9210-065-H-8-08 Page 45