SECTION 3 - ADJUSTMENTS
The switch settings and adjustments in this chapter should be made after your installation and wiring
to the operator(s) is complete. Whenever any of the programming switches on the circuit board are
changed, power must be shut-off, and then turned back on for the new setting to take effect.
3.1 Circuit Board Adjustments
Set the DIP-switches on the circuit board to the desired setting. See switch-setting charts in section
3.2.
Auto close timer (when turned on) can be set from 1 second (full counter clockwise) to approximately
23 seconds (full clockwise).
Dry contact relay (terminals 11-12) can be set for Normally Open (NO) or Normally Closed (NC)
operation by placing the relay shorting bar on the NO or NC pins respectively.
Power LED indicates that low voltage power is applied to the circuit board.
Input LEDs should be OFF and will only illuminate when the input is activated.
The limit LED will be ON when the respective limit switch is activated.