Model DP569 User’s Manual Error Messages
D–3
NOT VALID: CHECK
CODING DELAY
Internal 44.1 kHz has been selected as the Clock Source and the current
Coding Delay is Internal with a delay value less than 204 ms, or Internal 32
kHz has been selected and the current delay value less than 280 ms.
NOT VALID: CHECK
OUTPUT MODE
The Multiplex Mode has been Enabled and the current Output Mode is Pro
32-bit or Consumer.
NOT VALID: CHECK
OUT OF RANGE
A new Coding Delay value has been selected and the new internal coding
delay parameter is not in the range “187”–“450”.
The Unit Address is out of range.
NOT VALID: CHECK
GPIO INPUTS
Bypass Mode has been Disabled and the bypass function is currently
activated through the rear-panel GP I/O connection.
NOT VALID: PRESET
RECALL PENDING
Time Code Ctrl has been selected as the Encoder State and a time code
controlled preset recall is currently Pending.