Model DP569 User’s Manual Front-Panel Menus
4-9
Bypass Mode
Is used to route the output of a secondary (standby) encoder to the switched audio
output of the primary encoder. See Section 3.1.5.

4.2.6 System Settings

This menu gives you access to submenus controlling communication with other
devices, and for upgrading software.
The submenus are:
Remote Baud Rate
Unit Address
Unit Name
Test Tone
Firmware Upgrade
Remote Baud Rate
Sets the baud rate for remote port communications.
Unit Address
The unit address is four characters long. The first character is limited to the numbers
8–F, and the other characters are restricted to 0–F. The last character must be even.
Unit Name
Assign any text name you wish to your DP569; this is displayed on the top line of the
main status menu.
Test Tone
Activates an internally generated test signal as the input to the encoding process rather
than the currently selected input signal. In order to get a valid Dolby Digital output,
encoding must also be active, which requires that the selected clock source be valid.
Firmware Upgrade
Enter the firmware upgrade menu when you have an upgrade to install. Download
status information is displayed while in progress and when completed. See the
documentation that accompanies the upgrade kit.