Model DP569 User’s Manual DolbyRemote
5-6
Make sure that you are either using a RS-232 connection through the front panel or a
RS-485 connection through the rear panel.
Verify that the baud rate and device address of the unit to be controlled match the
parameters given to the DolbyRemote application in the Open Device window. On
the unit, these parameters are found in the System Settings section of the DP569
setup menu.
It is possible that hardware constraints on the controlling PC can cause problems
with the remote connection. The DolbyRemote application transfers data
continuously to update dynamic information such as meter values. If the port is using
a shared IRQ with another device, then it is possible that the connection may be lost.
In this case using another COM port can solve the problem.
If the connection is lost, the unit will continue to operate with the current set of
parameters contained immediately before the connection was broken; it is not
advisable, however, to use the unit in this way if this problem persists.