Dometic 3000 Series owner manual Wiring Diagram, TOILET OPERATION CORRECTIVE PROCEDURES cont’d

Models: 3000 Series

1 16
Download 16 pages 21.74 Kb
Page 12
Image 12
TOILET OPERATION CORRECTIVE PROCEDURES (cont’d)

ELECTRICAL TROUBLESHOOTING (cont’d)

TOILET OPERATION CORRECTIVE PROCEDURES (cont’d)

Symptom: Water will not enter the bowl when the Flush Handle is raised to add water.

Place the Water Level Switch in "Low" position and flush toilet. Check status light LED 7 (Add Water) while lifting up the Flush Handle.

If LED 7 comes on, replace the Control Module.

If LED 7 remains off, the Flush Switch or its related wiring is defective.

Symptom: Water Level Switch has no effect on water level in "Low" or "High" position.

Replace the Control Module.

Symptom: Flush Ball will not open when Mode Switch is in the "Service" position.

Replace the Control Module.

WIRING DIAGRAM

12

Page 12
Image 12
Dometic 3000 Series Wiring Diagram, TOILET OPERATION CORRECTIVE PROCEDURES cont’d, ELECTRICAL TROUBLESHOOTING cont’d