Figure 8.
11.Replacing the decorative door panel, Fig. 9
1
3
1
2
4
Figure 9.
Remove the mounter screws (1) of the forehead panel.(3)
Remove rosette (2) (in case of with lock version fridge). Lift and remove the forehead panel.(3)
Slide the decorative panel (4) out of the door frame and insert the new panel (thickness max. 2 mm).
Place back the forehead panel,rosette and screw in reverse sequence.
12. Customer service
Before you call a service engineer, carry out the following simple tests:
Is there a power failure? Check the fuses.
Is the plug firmly connected to the socket and is the socket switched on? Check the socket by plugging in another appliance, e.g. a table lamp.
Is the thermostat at the correct setting?
Has the door not been closed properly causing the inside temperature to rise too quickly?
Is the refrigerator level?
Has the ventilation become obstructed?
If after checking all the above points, the refrigerator is still not working satisfactorily, contact your nearest service engineer. State the problem, model, product- and
(Details of the model, product- and serialnumber are to be found on the data label in the top left of the inside compartment.)
This refrigerator is equipped with overheating protection. An authorised service technician can check whether this has been triggered or not.
In the event of a fault developing, contact your nearest Service
13. Putting into operation
Technical data:
Model | DS 300 H | DS 600 H |
Type | DS | DS |
Gross volume | 28,1 litre | 52,6 litre |
Mains operation | 220 - 240V (AC) | 220 - 240V (AC) |
Input | 65W | 85W |
Energy consumption | 0,76 kWh/24h | 0,88 kWh/24h |
Climate class | SN | SN |
Refrigerant | 151g H2O + 101g NH3 | 157g H2O + 105g NH3 |
13.1. Connecting to electrical mains
The appliance may only be operated from nominal voltage mains as shown on the data plate. The appliance mains plug may be connected to a mains socket earthed in accordance with
regulations.
Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person.
The manufacturer declines any liability should these safety measures not be observed.
Electrical Requirements
Before switching on, make sure the electricity supply voltage is the same as that indicated on the appliance rating plate.
Only for UK:
The appliance is supplied with a 3 amp plug fitted. In the event of having to change the fuse in the plug supplied, a 3 amp ASTA approved (BS 1362) fuse must be used. Should the plug need to be replaced for any reason, the wires in the mains lead are coloured in accordance with the following code:
Green and Yellow: | Earth |
Blue: | Neutral |
Brown: | Live |
7