INSTALLATION INSTRUCTIONS
12 V DC connection
The connection is made to the positive (+) and negative
The distance the current must travel from the battery to the refrigerator dictates the AWG wire size to be used. Should the wire be too small for the distance, a voltage drop will result causing a decreased cooling capacity.
For
Recommended wire sizes are displayed in the following table:
CONDUCTOR WIRE SIZE AND LENGTH |
| |||
WIRE | Size | Length |
| |
MODEL | AWG | ft | m | |
RM2351 | 14 | 17 | 5 | |
RM2451 | 12 | 27 | 8 | |
RM2551 | ||||
|
|
| ||
RM2652 |
|
|
| |
RM2662 |
|
|
| |
RM2852 |
|
|
| |
RM2862 |
|
|
| |
RM3862 |
|
|
| |
NDR1062 |
|
|
| |
RM2354 | 10 | 17 | 5 | |
RM2454 | 8 | 27 | 8 | |
RM2554 | ||||
|
|
| ||
RM2663 |
|
|
|
MOUNTING INSTRUCTIONS
REVERSING THE DOOR SWING
The refrigerator is equipped with hinges that makes it possible to change the direction the door opens by moving the hinges to the opposite side. A special hinge kit must be used in order to change the door swing. For conversion kit number, refer to the
USER MANUAL (825125700), APPENDIX B - SPARE PARTS
MOUNTING THE DOOR PANEL(S)
Optional door insert panels are available for
normally delivered without door panel(s).
Before starting the mounting work, read this instruction thor- oughly and check that the panel dimensions are in compliance with those given in the “Panel dimensions” table
Panel dimensions
max. thickness 5/32" (4 mm)
|
| Height |
| Width | ||
|
| max | min | max | min | |
UPPER |
|
|
|
|
| |
| mm 403 | 401 | 527 | 524 | ||
| inch | |||||
|
|
|
|
|
| |
LOWER / |
|
|
|
|
| |
SINGLE |
|
|
|
|
| |
DOOR |
|
|
|
|
| |
RM2351 | mm | 642 | 640 | 498 | 496 | |
RM2354 | ||||||
|
|
|
|
| ||
| inch | |||||
RM2451 | mm | 827 | 825 | 527 | 524 | |
RM2454 | ||||||
|
|
|
|
| ||
RM2652 |
|
|
|
|
| |
RM2662 | inch | |||||
RM2663 | ||||||
|
|
|
|
| ||
RM2551 | mm | 983 | 981 | 527 | 524 | |
RM2554 | ||||||
|
|
|
|
| ||
RM2852 |
|
|
|
|
| |
RM2862 | inch | |||||
NDR1062 | ||||||
|
|
|
|
|
- 9 -