Dometic RM2451, RM2551 Drain Water Hose, CONNECTIONS Gas connection, Installation Instructions

Models: RM2351 RM2451 RM2551

1 16
Download 16 pages 43.16 Kb
Page 7
Image 7
driver (both sides).

INSTALLATION INSTRUCTIONS

b)Secure the refrigerator and the lower front strip with two screws: One screw through the hinge and on the opposite side and then, one screw through the lower front strip.

2.Two screws installed in the top frame.

a)Remove the top decoration panel.

b)Open the door.

Gently push the tabs out of the hole in the hinge with a flat blade screw-

driver (both sides).

2

 

c) Carefully tilt the top

decoration panel and

 

lift to remove from top

1

frame. Be careful not to

 

damage the circuit board and wires.

d)Install the two screws in the top frame, the holes are accessible from underneath.

e)Seal the opening for the screws with aluminum tape.

f)Replace the top decoration panel. Be careful not to pinch the wires behind the panel. Make sure the tabs snap back into the holes in the hinge plate.

3.Two screws installed in the rear base.

DRAIN WATER HOSE

A hole must be drilled through flooring and the installer needs to make sure the hose does not kink when run through the floor. Seal around the hose that goes through the drilled hole. If a longer hose than supplied is required to get the water to drain outside of the vehicle, the installer will have to supply the extra length of hose.

RM2451-2454-2551-2554- 2652-2662-2663-2852- 2862-3862 & NDR1062

Hole for drain water hose

RM2351-2354

Hole for drain water hose

CONNECTIONS

Gas connection

Hook up to the gas supply line is accomplished at the manual gas valve, which is furnished with a 3/8” SAE (UNF 5/8” -18) male flare connection. All completed connections should be ex- amined for leaks using a solution of liquid detergent and water.

!WARNING

Be very careful when working on or near the gas sys- tem. Do not use an open flame to check for gas leaks!

The gas supply system must incorporate a pressure regulator to maintain a supply pressure of not more than 11 inches water column. When testing the gas supply system at test pressures:

> 1/2 psi - the refrigerator and its individual shutoff valve must be disconnected from the gas supply piping system.

≤ 1/2 psi - the appliance must be isolated from the gas supply piping system by closing its individual manual shut- off valve.

If detailed instructions on the installation and connection to the gas supply are required, please contact your dealer or distributor.