4.Attach terminal lugs to line 1 (black), neutral (white), and line 2 (red) wires. Loosen (do not remove) the setscrew on the front of the terminal lug and insert exposed wire end through bottom of terminal lugs. Securely tighten setscrew to torque as shown in the following Bare Wire Torque Specifications chart.
A
B
C D E
A. Terminal lug
B.Setscrew
C.Line 2 (red) wire
D.Neutral (white) wire
E.Line 1 (black) wire
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20
Wire Awg | Torque |
8 gauge copper | 25 |
|
|
6 gauge aluminum | 35 |
|
|
5.Use a hex or Phillips screwdriver to connect the bare (green) ground wire to the range with the
6.Use ³⁄₈" nut driver to connect the neutral (white) wire to the center terminal block post with one of the
G |
A |
B
| F | |
D | E | |
C | ||
|
A. | E. Neutral (white) wire |
B. Line 2 (red) | F. Line 1 (black) |
C. Bare (green) ground wire | G. Terminal lug |
D.
7.Connect line 2 (red) and line 1 (black) wires to the outer terminal block posts with
8.Securely tighten hex nuts.
9.Replace terminal block access cover.
3-wire connection: Direct Wire
Use this method only if local codes permit connecting ground conductor to neutral supply wire.
1.Pull the wires through the conduit on cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.
A
G
B
|
| C |
|
| D |
F | E |
|
|
| |
A. Terminal block | D. Line 2 | (red) wire |
B. | E. Bare (green) ground wire | |
C. Cord/conduit plate | F. Line 1 | (black) wire |
| G. Metal ground strap |
2.Attach terminal lugs to line 2 (red), bare (green) ground, and line 1 (black) wires. Loosen (do not remove) the setscrew on the front of the terminal lug and insert exposed wire end through bottom of terminal lugs. Securely tighten setscrew to torque as shown in the following Bare Wire Torque Specifications chart.
A
B
C D E
A. Terminal lug
B.Setscrew
C.Line 2 (red) wire
D.Bare (green) ground wire
E.Line 1 (black) wire
14