INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Tools needed
■ | Tape measure | ■ | Masking tape |
■ | ■ | ¼" nut driver | |
■ | Level | ■ | ⁵⁄₁₆" nut driver |
■ | Hammer | ■ | ¹⁄₈" (3.2 mm) drill bit (for |
■ Hand or electric drill |
| wood floors) | |
| ³⁄₁₆" (4.8 mm) | ||
■ | Wrench or pliers | ■ | |
| masonry drill bit (for | ||
|
|
| |
■ | Marker or pencil |
| concrete/ceramic floors) |
Parts supplied
Check that all parts are included.
A
B
A.
B.#12 x 1⁵⁄₈" screws
■
Parts needed
If using a power supply cord:
■A UL listed power supply cord kit marked for use with ranges. The cord should be rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening and must end in ring terminals or
■A UL listed strain relief.
Check local codes. Check existing electrical supply. See “Electrical Requirements” section.
It is recommended that all electrical connections be made by a licensed, qualified electrical installer.
Rear Filler Strip (optional)
The rear filler strip may be used to fill a gap between the rear of the
A
B
B
C
A. Rear filler strip
B.Countertop
C.Countertop cutout
Please reference the “Assistance or Service” section of the Use and Care Guide to order.
Black - W10113902A
White - W10113903A
Biscuit - W10113904A
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
■It is the installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located inside the oven door on the
■The range should be located for convenient use in the kitchen.
■To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood or microwave range hood combination that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets.
■Cabinet opening dimensions that are shown must be used. Given dimensions are minimum clearances.
■The
■Grounded electrical supply is required. See “Electrical Requirements” section.
IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C).