4.Drill two ¹⁄₈" (3 mm) holes that correspond to the bracket holes of the determined mounting method. See the following illustrations.
Floor Mounting
5.Using a Phillips screwdriver, mount the
6.Move the range close enough to the opening to allow for final gas and electrical connections. Remove the shipping base, cardboard or hardboard from under the range.
7.Move the range into its final location, making sure the rear leveling leg slides into the
Rear position | Front position | Diagonal (2 options) | 8. Move the range forward onto shipping base, cardboard or |
Wall Mounting |
|
| hardboard to continue installing the range using the following |
|
| installation instructions. | |
|
|
|
Electrical Connection - U.S.A. Only
Power Supply Cord
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death, fire, or electrical shock.
Direct Wire
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death, fire, or electrical shock.
1.Disconnect power.
2.Remove the terminal block cover screws located on the back of the range. Pull cover down and toward you to remove cover.
3.Remove plastic tag holding three
A |
A.
B.Terminal block cover
B
4. Add strain relief.
10