![5.2.2Electrical operation](/images/new-backgrounds/73648/7364813x1.webp)
5.2.2Electrical operation
1. 12V DC
The refrigerator should only be used while the motor is running.
1. Set energy selector switch (A) to.
The refrigerator operates without thermostatic | A |
| |
control (continuous operation). |
|
2. Mains power
This option should only be selected where the supply voltage of the connection for power supply corresponds to the value specified on the data plate.
Any difference in values may result in damage the appliance.
A
1.Set energy selector switch
(A)to.
B
2. Use rotary switch (B) to regulate the temperature in the main refrige- rator compart- ment.
5.2.3Gas operation
The refrigerator should only be operated using liquid gas (propane, butane). Do not use town gas or natural gas.
If the refrigerator is operated during travel using gas, the precautions stipulated by the legislation in the respective country must be taken (in conformity with the European standard EN 732).
Operating the refrigerator with gas is not permitted during travel in France and Australia.
As a basic rule, operation using gas is prohibited in petrol stations.
1.Open the valve of the gas cylinder
2.Open the
Proceed to the description that applies to YOUR model.
1. Manual ignition
1.Set energy selector switch (A) to gas.
A
3.Activate Piezo
C ignition (C) several times at intervals
2.Press and hold rotary switch.
B
4.Check the inspection glass to see whether there is a flame (the inspection glass is insi- de the refrigerator at the bottom left).
7