Dometic RM 6201(L), RM 6261(L), RM 6200(L), RM 6260(L), RM 6271(L), RM 7270(L) 6.9.3Wiring diagrams

Models: RM 7290(L) RM 7360(L) RM 7400(L) RM 6270(L) RM 6290(L) RM 6291(L) RM 7270(L) RM 6271(L) RM 6260(L) RM 6201(L) RM 6200(L) RM 6261(L)

1 28
Download 28 pages 39.35 Kb
Page 26
Image 26
6.9.3Wiring diagrams

6.9.3Wiring diagrams

1.Wiring diagram with manual ignition and no interior light.

battery connection DC

 

mains connection AC

 

 

 

 

 

 

heating- element

DC

thermo cut-off current

heating- element

AC

2. Wiring diagram with manual ignition and interior light

Battery connection 12V/24V -

 

 

A = Ground heating element DC, white

 

 

 

 

B = heating element DC-,

red

battery connection

C = Ground interior light,

black

12V/24V --

 

D = Interior light,

violet

 

heating- element DC-

resistor (replaced by a bridge for 24V battery voltage)

reed contacts (sensor switching)

thermo cut-off current

heating- element AC~

light DC --

mains connection ~

to casing

26

Page 26
Image 26
Dometic RM 6201(L), RM 6261(L), RM 6200(L), RM 6260(L), RM 6271(L), RM 7270(L), RM 6291(L), RM 6290(L) manual 6.9.3Wiring diagrams