Dometic RM 7371 L, RM 7365 L 6.9.5Retrofitting, AES only, D+ connection, Solar control input S+

Models: RM 7361 L RM 7405 L RM 7401 L RM 7275 L RM 7271 L RM 7371 L RM 7295 L RM 7365 L

1 28
Download 28 pages 34.83 Kb
Page 26
Image 26
6.9.3D+ connection and Solar Control connection

6.9.3D+ connection and Solar Control connection

( AES only )

D+ connection

The D+ control connection must be connected to the respective vehicle terminal (alternator signal while motor is running).

Solar control input (S+):

Connection only when using a solar system with a solar charging controller with AES output.

The respective solar charging controllers are available from a specialized dealer.

The “Solar” (S+) control connection must be connected to the respective terminal of the solar charging controller (AES output).

Cable cross-sections

There are no particularly high current flows via the D+ and S+ connection; therefore no particularly large cross-section is required for these connections (approx. 1mm²).

6.9.4 Terminal strip (RM 7XX1 L and RM 7XX5 L models)

Connections:

A = Ground heating element DC B = Plus heating element DC C = Ground electronics

D = Plus electronics

D+ = alternator signal

S+ = AES-input-control signal (solar charge regulator)

on the appliance

- + D+ S+ - +

C

 

D

 

A

 

B

 

 

 

 

 

 

 

on the vehicle

6.9.5Retrofitting