6.3Ventilation and extraction
A correct installation is important for correct operation of the appliance to ensure, there is no
In the event of high ambient temperatures, full performance of the cooling unit can only be achieved by means of adequate ventilation and extraction.
x = 110mm min
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
without step |
| with step |
Ventilation is provided for the unit by means of two apertures in the caravan wall. Fresh air enters at the bottom, extracts the heat and exits through the upper vent grille.
The upper ventilation grille should be positioned as high as possible above the condenser (A) .
The lower ventilation grille should be flush with the floor of the vehicle, allowing any gas leakages (heavier than air) to escape directly into the open air.
If such an arrangement is not possible a hole must be provided by the manufacturer of the vehicle under the refrigerator (not close to the burner) so that any leaking LP gas can escape. This must have an effictive area of at least 13cm². It is desirable to fit the hole with wire mesh or similar, and an angle plate to protect it from stones, mud etc., the wire mesh must not reduce the effective area of 13cm².
The ventilation grilles must have an open
Comment:
If the distance between the wall and the refrigerator is greater than 20mm the gap can be reduced to 20mm by fitting a suitable baffle piece.
Correct mounting of the lower ventilation grille facilitates the access to the electrical and gas connections during maintenance work.