6.7Fume extraction

6.7Fume extraction

Fume extraction must be arranged in such a way as to provide complete extraction of all products of combustion to an area outside the living area.

The flue system must slope in an upward direction in order to avoid a build-up of condensation.

An installation that is not carried out by qualified persons causes a reduction in the cooling capacity and will jeopardize the manufactur- er's guarantee.

6.7.1Fitting the fume flue in the upper ventilation grille

min. 10 mm max. 20 mm

1.Connect T-piece (E) to adaptor (F) or tail pipe (K) as required and affix with screw (G). Ensure that heat baffle (H) is lodged in the correct position.

2.Insert flue pipe with cover plate (C) through the appropriate aperture in frame (I) and connect to T-piece (E). If necessary, shorten flue pipe (C) to the required length.

3.Insert ventilation grille(D) into mounting frame (I) and fasten, using the locking handle on the left of the grille.

4.Insert extractor insert (A) into ventilation grille (D).