6.8Gas installation
The rules in point 6.1 must be adhered to.
When running on gas, these appliances are intended exclusively to use liquid gas (propane) - under no circumstances should town gas or natural gas be used.
An AGA Approved LP Regulator must be fitted to the gas supply.
The pressure regulator must concur with the operating pressure specified on the data plate of the appliance. The operating pressure corresponds to the standard pressure of the country of specification.
Only one connection pressure is permissible for any one vehicle. A plate showing the permanent, clearly legible notice must be displayed in full view at the point where the gas cylinder is installed.
This appliance is not suitable for connection with a Flexible Hose.
Inflamable material should not be in immediate proximity to the burner.
The gas connection to the appliance is 1/8"BSP Female.
The gas connection may only be carried out by authorized personnel.
Before Leaving - Check all connections for gas leaks with soap and water. DO NOT use a naked flame for detecting leaks. Ignite the burner to ensure correct operation of gas valve, burner and ignition. When satisfied with the appliance, please instruct the user on the correct method of operation. In case the appli- ance fails to operate correctly after all checks have been carried out, refer to the authorised service provider in your area.
ATTENTION
15 Nm |
| 20 Nm |
max |
| max |
|
|
|
Test point
Gas burner
Connection of gas supply
SW 14 SW 17
The refrigerator must be equipped with a gas cock in the supply line to allow the supply to be disconnected. Such a
Gas pressure
Refer to data label for test point pressure.