2.4 Instructions for the electrical connection

Installation instructions 2

GB

2.4 Instructions for the electrical connection

 

The Dometic generator is a source of alternate 230V 50Hz tension, able to cope with various power needs.

Cross-section mm2

Cross-section mm2

Cross-section mm2

Cross-section mm2

230V

12V

Lenght up to 6m

Lenght > 6m

(power cables)

(battery charger)

(battery connection)

(battery connection)

 

 

 

 

4

2.5

16

25

Electrical connection to the external network

The on board electrical system must be fitted with a relay or switch (e.g. Dometic switch cod. AG113, available on request) to prevent damage to the generator when the external power supply network is connected; in this case, it is suggested that the generator be connected in such a way as to give it priority with respect to the external network.

Electric wiring must be effected in conformity with the existing laws and regulations in force in the user’s country.

For correct installation performed by the final user, use preventive technical assistance by your seller or by a skilled technician.

For the 230 V, use an approved cable with the section indicated in the table. For connection of the Dometic switch cod. AG113 refer to the instructions and diagram on the following pages.

Electrical connection of the battery charger

External control panel socket

Emergency stop switch

230V

plug

Earth wire

12 V plug for battery charger

Socket for tank float wire

The unit is set up to provide for automatic battery recharging. If this function is to be used, proceed as follows.

Use a cable finding the correct section in the chart on the right. Connect the cable to the connecting terminal and to the positive pole of the battery to be charged.

Should the battery be others than that used to start the generator, then connect the negative pole of this battery to the proper mass point of the generator (see picture on page 17).

NB:The negative pole of the battery should be grounded with the

vehicle’s frame.

Cut out switch

Connecting the fuel indicator

Only use the indicator connection if there is a fuel level probe in the tank used for the generator. Connect the proble cable (e.g. float) to the relevant terminal (see figure above).