Installation/Operating Instructions
220V SL & SLX Scissor Lift Video Projector Lift by Draper
These Installation/Operating Instructions are available in the official language of the country where you purchase the product. Please contact your distributor to request a copy.
Vous pourriez demander les instructions d’installation et d’opération traduises dans la langue officielle du pays ou vous achetez le produit. Veuillez demander à votre distributeur.
Die Gebrauchsanweisung für Installation und Konstruktion sind in der offiziellen Sprache des Landes, indem Sie das Produkt gekauft haben, vorhanden. Fragen Sie die jeweilige
Caution:
➀Read instructions completely before proceeding.
➁ Test lift prior to installation.
➂ Follow instructions carefully. Installation contrary to instructions invalidates warranty.
➃ Do not obstruct operation of Scissor Lift with fi ngers or any object. Serious injury or damage could result.
➄ Scissor Lift is designed to accommodate ceiling suspended equipment. Equipment should not be allowed to rest on optional ceiling closure during operation. (Refer to section titled “Installing Projector.”)
➅ Entire bottom of unit must be unobstructed to permit proper operation. Suffi cient clearance must be allowed below projector or optional ceiling closure: see chart on page 4.
➆ Unit must be installed level (use a carpenter’s level).
➇ Unit operates on 220V, 50 Hz. AC current.
Note: Unit has been thoroughly inspected and tested at factory and found to be operating properly prior to shipment.
➂Fastening methods must be suitable for mounting surface, and securely anchored so that vibration or abusive pulling on unit will not weaken
installation.
➃Unit should be level, with weight shared more or less equally by all four
threaded mounting rods.
➄Bottom of unit must be unobstructed after installation. Suffi cient clearance must be allowed below projector or optional ceiling closure: 4' for Model
SL4, 5' for Model SL5, etc.; 11' for Model SLX11, 12' for Model SLX12, etc.
➅Do not use unit to support adjacent ceiling, light fi xtures, etc.
➆Do not complete the ceiling below unit until electrical connections have
been completed and unit has been operated successfully.
➇We recommend that safety cables be attached to the Scissor Lift for added security (a sound installation practice with overhead equipment).
Electrical Connections
Unit operates on 220V AC, 50 Hz. current. Removing the top cover of the unit and opening the electrical box exposes terminals for fi eld connections. Unit is shipped with internal wiring complete. Wire to connect unit to power supply should be furnished by installer. Connections should be made in accordance with wiring diagram, and wiring should comply with national and local electrical codes. All operating switches should be “off” before power is connected.
Scissor Lift should be operated and checked prior to installing projector and/or optional ceiling closure.
Standard switch shown below comes with 22.86 meters of cable and should be plugged in to box on front of top pan of lift to control lift.
Planning
➀Based on screen location and projector specifi cations, determine proper position for projector installation.
➁Confi rm that there is adequate space for installation and operation. Minimum clearance above ceiling level varies according to Scissor Lift
model, plus height of projector, optional mounting bracket, optional ceiling closure, and optional plenum rated housing.
➂Arrange to provide service access to the unit.
UP
OFF OFF
DOWN
|
| As Soon As Scissor Lift Arrives | Operation | |||||||||
➀ Open carton and inspect for damage. |
|
| When unit is fi rst operated, be cautious! If unit fails to operate when toggle | |||||||||
➁ Locate the following parts: |
|
|
|
|
| switch is fl ipped “down”, return switch to “off” and recheck electrical | ||||||
A. The unit itself |
|
|
|
|
| connections before proceeding. Cycle unit down and up several times to | ||||||
B. Controls |
|
|
|
|
| |||||||
|
|
|
|
| confi rm satisfactory operation. | |||||||
C. Any optional equipment: plenum housing, closure panel, ceiling fi nish kit | ||||||||||||
Standard Single Station Control (CE | ||||||||||||
or decorative cover (all ship in separate cartons). |
|
| ||||||||||
|
| moving | ||||||||||
➂ Test lift prior to installation. |
|
| ||||||||||
|
| toggle switch to “up” will start lift up. When lift is in “show” position, travel will | ||||||||||
|
|
|
|
|
| Hanging Unit |
|
| ||||
|
|
|
|
|
|
|
| automatically be stopped by factory set limit switches. Whenever switch is | ||||
The Scissor Lift may be installed in a variety of ways; recessed above the | placed in center “off” position, operation will stop. One, 12V key switch will | |||||||||||
ceiling, or suspended below the ceiling. The lift should be supported by four | lower lift from “show” to “service” position. | |||||||||||
½" threaded mounting rods. If ceiling recessed, the entire unit (including | Video Interface Control (CE | |||||||||||
the projector) should set approximately 1½" above the fi nished ceiling in its | allows the Scissor Lift switch to control the operation of a Draper motorized | |||||||||||
“stored” position. The threaded rods should pass through the corner mounting | ||||||||||||
projection screen via a relay. | ||||||||||||
fl anges and be secured by nuts above and below. Use a thread locking | ||||||||||||
Multiple Station Control (Not CE | ||||||||||||
compound such as Loctite® #242 (provided). The unit should then be guy | ||||||||||||
wired or blocked to prevent swinging. |
|
| “stored” to “show” position only. Each switching station has a | |||||||||
|
| with “up”, “down”, and “off” buttons. Lift starts up or down when appropriate | ||||||||||
All installations should observe the following guidelines: |
|
| ||||||||||
|
| button is pressed, and may be stopped by pressing “off” button. Factory set | ||||||||||
➀ Access from above the unit, with enough clearance to remove the top | ||||||||||||
cover, should be provided in case service is required. If installing above a | limit switches stop lift automatically when projector is in “show” position. | |||||||||||
hard ceiling, optional Draper Access Panels are available to allow access to | Key Operated Switch (Not CE | |||||||||||
the unit. |
|
|
|
|
| operated three position (up/off/down) switch is available. Multiple Station Con- | ||||||
➁ Installer must ensure that all fasteners and supports are of adequate | trol required for this option. Moves lift from “stored” to “show” positions only. | |||||||||||
strength to securely support Scissor Lift and projector. |
|
| Infrared or Radio Frequency Remote Control (CE | |||||||||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| starts up or down when appropriate button is pressed, and may be stopped by | |
® |
|
|
|
|
| pressing “off” button. Factory set limit switches stop unit automatically when | ||||||
|
|
|
|
| projector is in “show” position. Only controls "show" and "stored" positions. | |||||||
|
|
|
|
|
|
|
|
|
|
| Loctite® is a registered trademark of Henkel Corporation. | |
|
|
|
|
|
|
|
|
|
|
| If you encounter any difficulties installing or servicing your Scissor Lift, call your | |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| ||
Copyright © 2008 Draper Inc. | Form ScissorLift_220VInst08 | Printed in U.S.A. | dealer or Draper, Inc. in Spiceland, Indiana, |