SPECIFICATIONS

ULTRA FLAME DV “0” Clearance Fireplace

 

SPECIFICATIONS

Dimensions:

height 39", width 36", depth 20"

Glass:

29-1/8" x 17-3/4" 1400oF clear ceramic

Minimum opening in wall for installing the units: height: 39-1/2"

width: 36-1/2"

Fuel:

Natural Gas

Propane

 

Input :

30,000/ 20,000

26,000/20,000

Btu/h

Manifold pressure :

3.5/1.8

 

10.5/7.0

in w.c.

Min. inlet pressure :

5

 

11

in w.c.

Max. inlet pressure :

7

 

14

in w.c.

Efficiency:

75%

 

 

 

Vent size:

4" inner 8" outer coaxial vent pipes

 

Valve:

SIT Model Nova 820 adjustable millivolt valve

 

Blower:

Variable speed, 200 CFM

 

 

Thermo-switch:

120oF "ON", 90oF "OFF" bi-metal type

 

Pressure relief device: Burst disc

 

 

 

Maximum length of venting pipe allowed:

 

 

Straight out installation:

- Vertical rise: 0’

 

 

 

- Max horizontal length: 5'

 

 

 

- Max combination of both: 5’

 

Corner installation:

- Vertical rise: 0’

 

 

 

- Max horizontal length: 5'

 

 

 

- Max combination of both: 5’

 

Basement installation:

- Max vertical rise: 25'

 

 

 

- Max horizontal length: 10'

 

 

 

- Max combination of both: 25'

 

Maximum number of elbows 90° or 45°: 3