MAINTENANCE INSTRUCTIONS

ULTRA FLAME DV “0” Clearance Fireplace

MAINTENANCE INSTRUCTIONS

TURN OFF THE GAS WITH THE SHUTDOWN VALVE AND DISCONNECT THE ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.

The venting system and the gas fireplace should be inspected at least once a year.

Remove the glass front and the logs and clean them if necessary.

The control compartment, air circulating passages, firebox, logs and burner should be cleaned at least once a year by vacuuming or brushing.

Check the pilot flame to see if it is adjusted properly. Readjust the pilot flame if necessary (as described below) or clean the pilot orifice if readjustment is not possible.

Check the burner for flame lifting or for unusual flame pattern. If necessary clean the burner orifice. For more information, see “Adjustments” in the INSTALLATION section.

Keep the area clear and free from combustible materials, gasoline and other flammable vapours and liquids.

GLASS MAINTENANCE

We have supplied your ULTRA FLAME with special ceramic glass which will withstand the heat from the unit without cracking. Be careful not to hit the glass.

NOTE:

Never clean this glass with abrasive cleaners.

Use only a cleaner recommended by your dealer.

Never clean glass while it is still hot.

Do not operate the fireplace with the glass broken or removed

For removing your glass front see page 22.

If Your Glass Breaks:

See your dealer for exact replacement glass.

Remove front as explained above. With a 5/16” nut driver remove all nuts holding the glass retainers. Carefully remove retainers and seal.

After removing all broken glass pieces, insert new glass and reinstall seal and brackets. It the seal is damaged, replace it with an identical new seal from your dealer.