Connection to the control signal terminal (continued)

 

 

 

 

Command data

 

 

 

 

 

 

Item

 

 

 

 

Data code

 

 

MOUSE

00h=stop mouse emulation. 01~7Fh=start mouse emulation

 

 

 

COMMUNICATE

0Xh=8N1, 1Xh=7N1

 

X0h=1200bps, X1h=2400bps, X2h=4800bps, X3h=9600bps, X4h=19200bps

 

 

 

POWER

3Eh=Power off (Standby mode), 3Fh=Power on

 

 

MIRROR

00h=Normal, 01h=H:Invert, 02h=V:Invert, 03h=H&V:Invert

 

 

INPUT

11h=VIDEO, 21h=RGB1, 22h=RGB2

 

 

 

VIDEO SYSTEM

00h

00h=Auto, 00h 01h=NTSC, 00h 04h=NTSC4.43

00h

02h=PAL, 00h 03h=SECAM, 00h 05h=M-PAL, 00h 06h=N-PAL

 

 

 

 

 

VOLUME

00h

(min) ~ 24h (max)

 

 

 

 

MUTE

00h=Mute off, 01h=Mute on

 

 

 

 

 

 

BRIGHT

00h

00h

00h

(dark) ~ 00h 00h 24h (brite)

 

 

 

 

 

CONTRAST

00h

00h

00h

(lower) ~ 00h 00h 24h (higher)

 

 

 

 

 

COLOR

00h

00h

00h

(less) ~ 00h 00h 24h (more)

 

 

 

 

 

TINT

00h

00h

00h

(red) ~ 00h 00h 24h (green)

 

 

 

 

 

SHARPNESS

00h

00h

00h

(soft) ~ 00h 00h 24h (sharp)

 

 

 

 

 

 

H. PHASE

00h

00h

00h

~ 00h 00h 1Fh

 

 

 

 

 

H. POSIT

00h

00h

4Fh 00h (left) ~ 00h 00h 17h 05h (right)

 

 

 

 

 

H. SIZE

00h

00h

06h

06h (narrow) ~ 00h 00h 04h 0Ch (wide)

 

 

 

 

 

V. POSIT

00h

00h

03h

00h (down) ~ 00h 00h 00h 06h (up)

 

 

 

 

 

COLOR BALANCE

00h

00h

00h

(for Red) ~ 00h 00h 24h (for Blue)

 

 

 

 

AUTO ADJUST

00h

(start) , 07h (stop)

 

 

 

 

 

0Xh=Blank off, 1Xh=Blank on

 

BLANK

bit0 0=Blue off, 1=Blue on,

bit1 0=Green off, 1=Green on

 

bit2 0=Red off, 1=Red on,

bit3 0=Not change, 1=change

 

 

REVEAL

X1h=Reveal down, X4h=Reveal right, X=0 (slow) ~ 7 (fast)

(1)Circuit codes when ask code and default set code are issued (Number of data byte=1)

00h=normal display, 01h=magnified display

(2)When magnification is set by setting codes (Number of data bytes=6)

 

1st, 2nd data bytes: magnification starting positions in horizontal direction (left end)

MAGNIFY

00h

00h

(left) ~ 3Ch 05h (right)

 

3rd, 4th data bytes: magnification starting positions in vertical direction (top)

 

00h

00h

(top) ~ 0Dh 04h (bottom)

 

5th, 6th data bytes: Horizontally magnified dot number data

 

64h

00h

(large) ~ 20h 06h (small)

 

 

FREEZE

00h=normal display, 01h=still picture display

Caution If computer sends the undefined command code or data code, Projector can not guarantee operation.

Command is consisted of 2 command bytes and following data bytes.

1-st byte indicates the kinds of commands and the length of command.

'0xH' : Error-reply

Projector sends to computer.

'1xH' : Command reply

Projector sends to computer.

'2xH' : Ask command

Computer sends to Projector.

'3xH' : Set command

Computer sends to Projector.

'4xH' : Default set command

Computer sends to Projector

'5xH' - 'FxH' : Reserved

 

'x' indicates the length of data bytes.

2-nd byte indicates the command code 'yy' as command table.

26 Data table shows the data byte.

Page 26
Image 26
Dukane 28A8035 manual Command data