RS-232C external control

Specifications

RS-232C external control

By connecting a computer to the projector with a RS-232C cross cable (D-sub 9 pins), you can control the projector with the computer. The commands to control the projector and the response data format against the received commands are explained here.

For details, please consult the authorized dealer where you purchased your projector.

1.Communication Specifications

The communication specifications are as follows.

Baud rate

9600bps/19200bps

 

 

Data length

8 bits

 

 

Parity

None

 

 

Stop bit

1 bit

 

 

Flow control

None

 

 

2.Command Format

2-1 Command data format

When sending a control command to the projector, use the following data format.

Header

Header

ID

SP

CR

ID

 

SP

 

Command

[

SP

 

Parameter

[

CR

:Designates the head of data and the data type.

:‘!’ (21h): Assigns command to the projector.

:‘?’ (3Fh): Query to the projector. (Asking command)

:‘1’: The identification number of the projector. (Manufacturer set value ‘1’)

:Designates the delimiter for ID, Command, and Parameter. (20h)

:Designates the terminal of the data. (0Dh)

* [ ] is not necessary for Asking command.

2-2 Response data format

Upon executing a control command it has received, the projector sends back the following response data to the computer:

Header

 

ID

 

SP

 

Normal Termination Status

[

SP 1.Communication Specifications2.Command Format Parameter

[

CR

Header

: Designates the head of data.

 

: ‘@’ (40h): Fetches data from the projector.

 

 

ID

: ‘1’: The identification number of the projector. (Manufacturer set value”1”)

 

 

SP

: Designates the delimiter for ID, Command, and Parameter. (20h)

 

 

Normal Termination Status

: ‘0’ (30h)

 

 

CR

: Designates the terminal of the data. (0Dh)

 

 

2-3 Parameters used for the data format

The following three kinds of parameters are used for control commands and response data.

1)Numeric value

2)ON/OFF

3)Special parameters

Each parameter is as follows:

1) Numeric value

A 2-byte hexadecimal value (sign included) is represented by a set of 4 digit (4 bytes) characters. Designated range: ‘8000’ to ‘7FFF’.

2) ON/OFF

Shows the status (ON/OFF) of the projector, such as POWER and HIDE.

Character

Hex.

Meaning

 

 

 

‘0’

30

OFF

 

 

 

‘1’

31

ON

 

 

 

55

Page 55
Image 55