Video image is fuzzy.

Is the focus adjusted correctly?

• Adjust focus with the focus ring of the lens.

26

 

 

 

 

 

Is the projector placed too near or too far from

• Set the projector at the correct distance.

17

 

the screen?

 

 

 

 

 

 

 

Are “Tracking” and “Phase” adjusted correctly?

• Adjust “Tracking” and “Phase” using the menu.

37

 

 

 

 

Video image is ab-

Is the “Brightness” adjusted correctly?

• Adjust “Brightness” using the menu.

37

normally dark or

 

 

 

bright.

 

 

 

 

 

 

 

Color is poor or un-

Is the picture quality (color density, etc.) ad-

• Adjust picture quality using the menu.

37

stable.

justed correctly?

 

 

 

 

 

 

 

Is the correct “Decoder” selected?

• Set the “Decoder” to “AUTO” or the correct

38

 

 

dedicated decoder.

 

 

 

• If the problem is not rectified after setting to

 

 

 

“AUTO”, set to forced dedicated mode.

 

 

 

 

 

 

Are signals (scanning frequency, etc.) from the

• Check if the signal is appropriate (scanning

19, 20

 

connected device appropriate?

frequency, etc.), and input the appropriate sig-

 

 

 

nal.

 

 

 

 

 

 

Is the [PC2] input terminal being used?

• When the [PC2] input terminal is being used,

39

 

 

“PC2(BNC)” must be selected from the

 

 

 

“Options” menu. Set it correctly according to

 

 

 

the input signal.

 

 

 

 

 

The upper part of the

If the input signal comes from a computer sys-

• Input separate sync signals for vertical sync

19, 20

video image bows or

tem, is this a sync signal of composite sync (Cs)

(V) and horizontal sync (H) signals.

 

distorts.

or G on sync type?

 

 

 

 

 

 

 

Are signals with much jitter or skew distortion

• Input signals with little jitter or skew distor-

—————

 

being input from a video deck?

tion.

 

 

 

• Use a TBC or a device with a built-in TBC.

 

 

 

 

 

Remote control unit

Are batteries installed correctly?

• Match the polarities of batteries correctly, as

14

does not work.

 

shown on the battery cartridge.

 

 

 

 

 

 

Are batteries exhausted?

• Replace with new batteries.

14

 

 

 

 

 

Is there an obstructive object between the re-

• Remove any shielding objects.

18

 

mote control unit and the remote sensor?

 

 

 

 

 

 

 

Is the remote control held too far from the sen-

• Use the remote control unit at a nearer point.

18

 

sor?

 

 

 

 

 

 

This projector uses a micro computer. External noise may cause it to malfunction. If this happens, unplug from the main power outlet and then plug on again. (page 25, 27)

52

Page 52
Image 52
Dukane 9100HC manual Troubleshooting, Symptom Probable cause Corrective action

9100HC specifications

The Dukane 9100HC is a cutting-edge ultrasonic welding system designed for high-performance applications in the healthcare and industrial sectors. Built to facilitate reliable and precise joining of thermoplastic materials, this advanced machine integrates several innovative technologies to ensure optimal performance and efficiency.

One of the standout features of the Dukane 9100HC is its enhanced ultrasonic technology. This system utilizes high-frequency ultrasonic waves, which generate localized heat at the interface of the materials being welded. This technology allows for faster welding cycles and minimizes the risk of damaging heat-sensitive components, making it ideal for applications that require delicate handling.

The 9100HC system is equipped with a user-friendly touchscreen interface, providing operators with easy access to important functionalities. This interface includes real-time process monitoring, allowing users to track key parameters such as temperature and amplitude during the welding process. Additionally, the system supports built-in data logging, enabling detailed analysis and quality assurance for critical applications.

Another significant characteristic of the Dukane 9100HC is its advanced energy management system. This system optimizes the energy used during the welding process, enhancing the overall efficiency and reducing operational costs. Moreover, the Dukane 9100HC is designed to accommodate a wide range of welding applications, thanks to its versatile tooling options. This adaptability makes it suitable for both small-scale operations and large manufacturing runs.

The machine's robust construction ensures durability and longevity, even in demanding environments. The compact design facilitates easy integration into existing production lines, while the ability to customize and configure the system according to specific production needs makes it a preferred choice among manufacturers.

Safety is paramount in Dukane’s design philosophy, and the 9100HC is no exception. It incorporates multiple safety features, including emergency stop buttons and protective enclosures, ensuring operator safety and compliance with industry standards.

Overall, the Dukane 9100HC represents a significant advancement in ultrasonic welding technology, delivering reliability, efficiency, and versatility to a wide array of applications within the healthcare and industrial sectors. With its innovative features and user-centric design, the Dukane 9100HC stands out as a premier solution for manufacturers seeking high-quality welding solutions.