13. DPA 4411 Specifications

 

 

 

 

 

Power supply on mains operation:

 

 

 

 

 

operation voltage

 

 

115 V / 230 V~ AC, ±10 %

 

mains frequency range

 

 

50 - 60 Hz

 

 

safety class

 

 

I

 

 

 

 

 

 

 

 

 

 

mains operation

Umains [V]

Imains [A]

Pmains [VA]

Pmains [W]

Pout [W]

Pv [W]

 

 

 

 

 

 

 

Standby

230

0,016

3,7

1,5

0

1,5

0idling

230

0,29

67

40

0

40

Normal operation (-10 dB)

230

1,64

377

275

40

235

Alarm (-3 dB)

230

3,25

748

585

200

385

Nominal conditions

230

4,39

1010

815

400

415

 

 

 

 

 

 

 

mains initial current inrush

 

 

< 36 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mains operation

Umains [V]

Imains [A]

Pmains [VA]

Pmains [W]

Pout [W]

Pv [W]

 

 

 

 

 

 

 

Standby

115

0,30

3,5

1,5

0

1,5

0idling

115

0,50

58

40

0

40

Normal operation (-10 dB)

115

3,28

377

275

40

235

Alarm (-3 dB)

115

6,50

748

585

200

385

Nominal conditions

115

8,78

1010

815

400

415

 

 

 

 

 

 

 

mains initial current inrush

 

 

< 20 A

 

 

 

 

 

 

 

 

 

 

Pmains[VA] =apparent power Umains*Imains, Pmains[W] =true power, Pout[W] =output power, Pv[W] =leakage power

Power supply on battery operation:

 

 

 

 

operation voltage

 

 

24 V DC, -10/+30 %

 

 

 

 

 

 

 

battery operation

UB [V]

IB [A]

Pi [VA]

Pout [W]

Pv [W]

 

 

 

 

 

 

Standby

24

0,06

1,5

0

1,5

0idling

24

1,1

26

0

26

Normal operation (-10 dB)

24

7,5

180

40

140

Nominal conditions

24

18

432

250

182

 

 

 

 

 

 

battery initial current inrush

 

 

< 3,9 A

 

 

 

 

 

 

 

 

Pi[W] = input power UB*IB, Pout [W] = output power, Pv [W] = leakage power

input characteristics: nominal input level

power output characteristics:

nominal output power with mains supply nominal output voltage

with mains supply

with battery supply at 24 V DC nominal load impedance

minimal allowable output impedance:

electronically balanced

775 mV = 0 dBu / 10 k ohms balanced, floating

4 x 100 W (according to IEC 268-3)

100 V ( 70 V / 50 V / 20 V )

79 V ( 56 V / 40 V / 16 V )

100 ohms ( 50 / 25 / 4 ohms)

100 W output power

200 W output power

 

 

 

 

 

100 V output

 

100 Ohm // 250 nF

50 V + 50 V output

50 Ohm // 500 nF

70 V output

 

50 Ohm // 500 nF

—————

—————

50 V output

 

25 Ohm // 1000 nF

—————

—————

20 V output

 

4 Ohm // 6250 nF

—————

—————

 

 

 

 

 

noise voltage (A-weighted)

 

-56 dBu

 

THD at PA NOMINAL

 

1 %

 

amplification frequency response

60 Hz .. 20 kHz

 