7.4 GROUND FAULT Indicator

7.4 GROUND FAULT Indicator

If, with built-in NRS 90207 a ground fault condition at one of the power outputs occurs, the corresponding red GROUND FAULT indicator (6) lights and a fault-message is transmitted to the PROMATRIX Manager DPM 4000. The power amplifier keeps up normal operation during the occurrence of this fault-type. After solving the problem, the GROUND FAULT indicator (6) can be reset by pressing the TEST button (3) or by sending the corresponding command via the serial port of the PROMATRIX Manager DPM 4000 (see PROMATRIX handbook) (see paragraph 9.2).

7.5 Meter Instruments And CLIP Indicators

The green LED-indicator -13 dB and 0 dB (1) as well as the red LED-indicator CLIP (2) allow the precise monitoring of output levels, providing the possibility to securely prevent distortion and clipping that could lead to damaging the connected loudspeaker systems.

-When during program peaks the red CLIP-LED (2) lights briefly, the maximum distortion-free output is gained.

-Whenever the CLIP-LED (2) lights continuously, the amplifier is driven into overdrive and the input level should be reduced.

-Overload or short-circuit at the output is the cause for the green LED-indicator (1) to beout or only briefly lit while at the same time the red CLIP-LED (2) blinks. In that case, please check the impedance of the connected load.

Caution

During normal operation, the red CLIP-LED (2) should hardly light and if, than only very briefly !

7.6 STATUS Indicator

The yellow STATUS-LED (14) that is located on the rear of the appliance lights briefly during normal operation when the DPM 4000 addresses a query to the amplifier. For further information, please refer to the PROMATRIX handbook.

8. Switching The Output Voltage (refer to qualified service personnel only!)

The DPA 4411 offers output voltages of either 20 V, 50 V, 70 V or 100 V. The output voltage is factory-preset to 100 V. Switching the output voltage to 20 V, 50 V or 70 V should only be carried out by qualified DYNACORD service personnel.

Caution

 

Unplug the mains cord and disconnect batteries before opening the appliance!

 

 

 

-for opening the appliance, please remove the 9 screws on the top of the appliance that lock the cover plate.

-the four output transformers 356762 are located on the left hand side of the appliance. They are numbered 1, 2, 3, and 4; starting from the rear cover plate of the appliance.

-for changing the output voltage (see diagram 6) you have to unsolder the orange wire attached to the transformer’s soldering tab 19 (100 V) and solder it instead to the required soldering tab (70 V, 50 V or 20 V).

-closing the appliance: use the 9 screws M3 x 6 DIN 7500 to reattach the cover plate.

diagram 6 Switching the output voltage at the

diagram 7 Output configuration settings of the

amplifiers (rear view)

output transformers 356762

 