Rear Panel Map - LOCAL
Earthquake Sound
1V
LEVEL
3V 0.2V
LOCAL BUS
1
2
3
1 | Level Controls |
| This feature adjusts the maximum desired output of the associated zone to prevent overpowering of small |
| speakers. |
| Note: This knob is |
2 | LOCAL/BUS Switch |
| It switches the audio source between LOCAL and common BUS. In LOCAL mode, the zone acts independently |
| from the rest of system by only amplifying the information fed through the associated RCA inputs. In BUS mode, |
| that particular zone will amplify the signal fed through the main BUS input (page 11 - feature 9). |
3 | Audio RCA Input |
| Individual stereo RCA inputs to drive signal into associated zones. Both RCA’s, LEFT and RIGHT, are active |
| when the STEREO/MONO switch is set to MONO (feature 4). Thus, you can use either RCA inputs. |
1
STEREO
MONO
IR IN
STATUS
GROUND
CI
4
5
Note: This RCA input also serves as an Auto Signal Sensing whenever there is a signal greater than 12mV |
present. |
4 | STEREO/MONO Selector |
| Switches the amplifier’s output between STEREO or MONO. |
| ∙In STEREO mode, the LEFT and RIGHT outputs operate independently at 75 Watts per channel at 4Ù |
| speaker load. Level, Gain, Auto Turn ON and MUTE are all common to both. |
| ∙In MONO mode, the LEFT and RIGHT stereo signals are summed internally for a single high power output. |
| You can drive two 4Ù speakers in this mode or a single 4Ù Bridged for maximum power of 150WRMS. Also, if |
| the source is already a mono signal, you may use either RCA, LEFT or RIGHT. |
5 | Keypad/Zone Connector |
| With four (4) removable conductors (IR IN, STATUS, GROUND and |
| connector accepts wire sized from 24 to 12 AWG. We recommend using the CAT5, CAT5E, CAT6 or CAT6E |
FFIFFI
BRIDGE
6
7
wires. |
∙IR IN – receive all types of IR signal transmitted through the Earthquake Keypad. It allows Volume up/down |
and mute function at the local amplifier. Also, it allows most IR signal to pass through the four |
repeaters of the Cinénova 16IR (page 11 - feature 12). |
∙STATUS – this connector delivers DC signal to the Keypad’s LED status indicator when the associated |
amplifier is ON. |
∙GROUND – for the Keypad. |
∙CI – Control Input is the communicator line used to control amplifier’s ON/OFF (Mute) status manually. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| L | R |
L | R | L |
| R | L |
| R | L |
| R | L |
| R | L |
| R | L |
| R | L | R | L | R |
|
|
|
|
|
|
|
|
| SPEAKER OUTPUT |
|
|
|
|
|
|
|
|
| |||||
L | R |
| L | R |
| L | R |
| L | R |
| L | R | L | R |
| L | R |
| L | R |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| FUSE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| M |
|
| M |
|
| M |
|
| M |
|
| M |
| M |
|
| M |
| M |
|
|
6Fault Fuse Indicator (FFI)
This LED indicates the safe operation of the amplifier’s internal circuit for the associated zone. Under normal condition, this LED is off. When it is lit, the fuse on the internal circuit of that associated zone is blown, usually due to a shorted circuit. Simply replace with the same size fuse. For your convenience, we’ve included four (4) additional fuses with every amplifier.
7Speaker Terminals
This screw type connector with four (4) removable conductors accepts wire sizes from 16 to 12 AWG. Observe the Polarity printed on the terminal. Observe the printed instruction above and below the Speaker terminal.
10