NEMA Contactors & Starters | 15 | |
IT. | ||
|
September 2003
Accessories
Auxiliary Contacts
Auxiliary Contacts are available for mounting on Eaton’s
Table 12. Auxiliary Contact Availability — Sizes 00 – 5
Top Mounted (Maximum Auxiliaries per Contactor/Starter)
Contactor/Starter Size |
|
|
| Contact | Catalog | Price | ||
|
|
|
|
| Type | Number | U.S. $ | |
Size 00, 0 | Size 1 | Size 2 | Size 3, 4 | Size 5 | ||||
|
|
| ||||||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
3 | 3 | 3 | 3 | — | 1NO | EMA13 | 21.70 | |
|
|
|
|
|
|
|
| |
3 | 3 | 3 | 3 | — | 1NC | EMA14 | 21.70 | |
|
|
|
|
|
|
|
| |
2 | 2 | 3 | 3 | — | EMA15 | 29.00 | ||
|
|
|
|
|
|
|
| |
2 | 2 | 3 | 3 | — | 2NO | EMA16 | 29.00 | |
|
|
|
|
|
|
|
| |
2 | 2 | 3 | 3 | — | 2NC | EMA17 | 29.00 | |
|
|
|
|
|
|
|
| |
2 | 3 | 3 | 3 | 3 | Logic Level | EMA70 | 34.25 | |
|
|
|
|
|
|
|
|
Other combinations: Single, Dual, Single; Dual, Single, Dual; and Dual, Logic Level, Dual For reversers, multiply quantities by two.
EMA13 | EMA14 | EMA15 |
| EMA16 | EMA17 | EMA70 | |||
3 | 1 | 13 | 21 | 13 | 23 | 11 | 21 | 4 | 2 |
NO | NC | NO | NC | NO | NO | NC | NC | NO | NC |
4 | 2 | 14 | 22 | 14 | 24 | 12 | 22 | 1 | 1 |
|
|
|
|
|
|
|
| Common | |
|
|
|
|
|
|
|
|
|
|
Table 14. IEC Ratings
|
| ||
|
|
|
|
Ue Voltage | le | Ue Voltage | le |
| Amps. |
| Amps. |
|
|
|
|
24 | 5 | 48 | 8 |
|
|
|
|
48 | 2.5 | 120 | 6 |
|
|
|
|
125 | 1.1 | 240 | 4 |
|
|
|
|
250 | .55 | 440 | 2 |
|
|
|
|
Table 15. NEMA A600 Ratings
Current | AC Voltage |
|
| |
|
|
|
|
|
| 120 | 240 | 480 | 600 |
|
|
|
|
|
|
|
|
|
|
Make and | 60 | 30 | 15 | 12 |
Interrupting |
|
|
|
|
|
|
|
|
|
Break | 6 | 3 | 1.5 | 1.2 |
|
|
|
|
|
Continuous | 10 | 10 | 10 | 10 |
|
|
|
|
|
Thermal | 10 | 10 | 10 | 10 |
|
|
|
|
|
Table 16. NEMA P300 Ratings
Current | DC Voltage |
|
|
|
|
| 125 | 250 |
|
|
|
|
|
|
Make and | 1.1 | .55 |
Interrupting |
|
|
|
|
|
Break | 1.1 | .55 |
|
|
|
Continuous | 5 | 5 |
|
|
|
Thermal | 5 | 5 |
|
|
|
Table 17. EMA70 Auxiliary Contact
|
| ||
|
|
|
|
Ue | Ie | Ue | Ie |
|
|
|
|
|
|
|
|
30 | .1 | 250 | .1 |
|
|
|
|
Figure 6. Connecting Diagram — Sizes 00 – 5
Table 13. Auxiliary Contact — Size 5
Auxiliary Contacts per
Max | Contact | Description |
| Catalog | Price |
| Type |
|
| Number | U.S. $ |
|
|
|
|
| |
|
|
|
|
| |
2 | 1NO | Base auxiliary (max. 1 per side) | C320KGS41 | 45.50 | |
|
|
|
|
| |
2 | Base auxiliary (max. 1 per side) | C320KGS42 | 61.50 | ||
|
|
|
|
| |
6 | 1NO | C320KGS41 or C320KGS42 required | C320KGS20 | 45.50 | |
|
| (max. 3 |
|
| |
|
|
|
|
| |
2 | 1NO Logic Level | C320KGS41 or C320KGS42 required | C320KGS20L | — | |
|
| (max. 1 |
|
| |
6 | 1NC | C320KGS41 or C320KGS42 required | C320KGS21 | 45.50 | |
|
| (max. 2 |
|
| |
|
|
|
|
| |
2 | 1NC Logic Level | C320KGS41 or C320KGS42 required | C320KGS21L | — | |
|
| (max. 1 |
|
| |
|
|
|
|
| |
2 | C320KGS41 or C320KGS42 required | C320KGS22 | 61.50 | ||
|
| (max. 1 |
|
| |
2 | C320KGS41 or C320KGS42 required | C320KGS22L | — | ||
|
| (max. 1 |
|
| |
|
|
|
|
|
|
3 | Front mounted only |
| EMA70 | 34.25 | |
|
|
|
|
|
|
Contact factory for availability. | For reversers, multiply quantities by two. |
Notes:
■Side Mounted — Maximum (10) Total Circuits
■Front Mounted — Maximum (6) Total Circuits
■Maximum 4 auxiliaries per side (base + 3 side mounted)
■EMASA/B _ _ have been superseded by the above Catalog Numbers.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1