Page 14
Image 14
5.8.4KF730P Input Connections

5.8.4KF730P Input Connections

There are two 4-terminal barrier strip connectors on the rear of each KF730P. The connectors are wired in parallel so that the second connector can be used to loop LF and MF/HF signals to additional KF730s. The connectors accept stripped wire ends or wire lugs.

LF MF/HF

-- + -- +

LOOP THRU

LF1 LF2

-- + -- +

LOOP THRU

5.8.5SB730P Input Connections

There are two 4-terminal barrier strip connectors on the rear of each SB730P. The connectors are wired in parallel so that the second connector can be used to loop the LF1 and LF2 signals to additional SB730s. The connectors accept stripped wire ends or wire lugs.

5.8.6Wire Gauge

LF MF/HF

--+ -- +

KF730P INPUT

LF1 LF2

--+ -- +

SB730P INPUT

The maximum recommended loudspeaker cable lengths for each wire gauge are based on maintaining an acceptable damping factor and minimizing power loss at the nominal load impedances listed. While wire gauges smaller than those listed may be used, damping factor reductions and power losses may become significant. The table includes the overall nominal load impedances where the subsystems in multiple enclosures are wired in parallel to one amplifier channel.

Maximum Cable Length

Nominal Input Z

AWG

MWG

50 ft / 15 m

16 ohm

16 AWG

16 MWG

100 ft / 30 m

16 ohm

14 AWG

16 MWG

200 ft / 60 m

16 ohm

12 AWG

20 MWG

300 ft / 90 m

16 ohm

10 AWG

25 MWG

>300 ft / >90 m

16 ohm

Not recommended

Not recommended

50 ft / 15 m

8 ohm

14 AWG

16 MWG

100 ft / 30 m

8 ohm

12 AWG

20 MWG

200 ft / 60 m

8 ohm

10 AWG

25 MWG

>200 ft / >60 m

8 ohm

Not recommended

Not recommended

50 ft / 15 m

4 ohm

12 AWG

20 MWG

100 ft / 30 m

4 ohm

10 AWG

25 MWG

>100 ft / >30 m

4 ohm

Not recommended

Not recommended

50 ft / 15 m

2 ohm

10 AWG

25 MWG

> 50 ft / > 15 m

2 ohm

Not recommended

Not recommended

(AWG = American Wire Gauge; MWG = Metric Wire Gauge)

Page 14 of 28 RD0169 (A) KF730 & SB730 OWNER’S MANUAL

Page 14
Image 14
EAW 5.8.4KF730P Input Connections, + --+, 5.8.5SB730P Input Connections, 5.8.6Wire Gauge, KF730P INPUT, SB730P INPUT

FAQ

What are the input connections for KF730P?

The KF730P has two 4-terminal barrier strip connectors wired in parallel, with the second connector used to loop LF and MF/HF signals to additional KF730s.

What are the input connections for SB730P?

The SB730P also has two 4-terminal barrier strip connectors wired in parallel, with the second connector used to loop the LF1 and LF2 signals to additional SB730s.

What is the recommended wire gauge for 16 ohm nominal input Z over 300 ft / 90 m?

For 16 ohm nominal input Z over 300 ft / 90 m, it is not recommended to use smaller wire gauges.