12

Drive Shaft

IMPORTANT

Lower and upper drive shaft must be lubricated with POWER BLENDXTM grease every 25 hours of operation, otherwise drive shaft assembly overheating and failure can result.

1.Remove gear housing locator screw (A).

2.Loosen gear housing mounting bolt (B).

3.Pull gear box from drive shaft housing.

4.Pull flexible cable from the drive shaft housing, wipe clean and re-coat with a thin coating [15 ml (1/2 oz.)] of POWER BLEND- XTM.

5.Slide the flexible cable back in the drive housing. DO NOT get dirt on the flex cable.

6.Position lower drive shaft (end without safety decal) into gear housing shaft mount.

7.Align hole in drive shaft housing with gear housing shaft hole (C), and seat lower drive shaft end into gear housing shaft mount. Install and tighten locator screw (A).

8.Tighten gear housing mounting bolt (B).

A

B

C