PRO ATTACHMENT SERIESTM
OPERATOR'S MANUAL 13
STARTING WARM ENGINE
The starting procedure is the same as Cold Start except DO NOT close the choke, and do not depress throttle trigger to wide open position.
WARNING DANGER
The attachment should not move at idle, otherwise serious personal injury may result.
NOTE
If attachment moves, readjust carburetor according to “Carburetor Adjustment” instructions in this manual or see your ECHO Dealer.
1.Stop Switch
Move stop switch button/lever (A) away from the STOP position.
2.Purge Bulb
Pump purge bulb (C) until fuel is visible and flows freely in the clear fuel tank return line. Pump bulb an additional 4 or 5 times.
3.Recoil Starter
Lay the unit on a flat area and keep movable attachment parts clear of all obstacles. Rapidly pull recoil starter handle/rope (D) until engine fires.
NOTE
If engine does not start after 5 pulls, use Cold Start Procedure.
A
C
D
STOPPING ENGINE
1. Throttle | A |
Release throttle and allow engine to return to idle before shutting |
|
off engine. |
|
2.Stop Switch
Move stop switch button/lever (A) to STOP position.
WARNING DANGER
If engine does not stop when stop switch is moved to STOP position, close choke - COLD START position - to stall engine. Have your ECHO dealer repair stop switch before using unit again.