Echo X7502026001, X750018671, SRM-266S manual Starting cold engine, Purge Bulb

Models: SRM-266 SRM-266S X750018671 X7502026001

1 36
Download 36 pages 62 Kb
Page 16
Image 16

16

starting cold engine

WARNING

The attachment will operate immediately when the engine starts, and could result in possible serious injury. Keep movable parts of the attachment away from objects that could become entangled or thrown, and surfaces that could cause loss of control.

1.Stop Switch

Move stop switch button (A) forward away from the STOP posi- tion.

2.Choke

Move choke lever (B) to Cold Start Position ().

3.Purge Bulb

Pump purge bulb (C) until fuel is visible and flows freely in the clear fuel tank return line. Pump bulb an additional 4 or 5 times.

4.Recoil Starter

Lay the unit on a flat area and keep movable attachment parts clear of all obstacles. Firmly grasp right hand grip and throttle trigger lockout with left hand and fully depress throttle trigger to wide open position. Rapidly pull recoil starter handle/rope (D) until engine fires (or maximum five [5] pulls).

5.Choke

After engine fires (or 5 pulls), move choke lever back to Run

() position. Hold throttle trigger and throttle trigger lockout fully depressed, and pull recoil starter starter handle/rope until engine starts and runs. Release throttle trigger, and allow unit to warm up at idle for several minutes.

NOTE

If engine does not start with choke in “Run” position after 5 pulls, repeat instructions 2 - 5.

6.Throttle Trigger

After engine warm-up, gradually depress throttle trigger to increase engine RPM to operating speed.

A

B

C

D

Page 16
Image 16
Echo X7502026001, X750018671, SRM-266S manual Starting cold engine, Purge Bulb