Setting the Temperature

Operation – Using the Control Panel

Setting the Temperature

1.Press the ‘Up’ or ‘Down‘ buttons to set the temperature you desire.

2.The display window will show the temperature you set as you press the 'Up' or ‘Down' buttons. Otherwise, it will always show the ambient temperature.

The default temperature of this machine is: 75o F for cooling

Note: Temperature control only works in cooling and heating modes.

Setting the Fan Speed

1.Press the ‘Speed’ button to choose between high or low. The high or low indicator will light on.

2.If the unit is in ‘Auto’ mode, it will choose the fan speed automatically according to the ambient temperature (the related indicators will light up). While in ‘Auto’ mode pressing the ‘Speed’ button will have no effect.

Setting the Timer to Automatically Shut Off the Unit

While the machine is running, press the ‘Timer’ button to set the number of hours you want to wait for the machine to shut off automatically. You are able to set the time between 1 to 12 hours by continuing to press the ‘Timer’ button. The timer indicator will light on. When the time set has elapsed, the machine will turn off automatically. The display window will show the hour(s) you set as you press the ‘Timer’ button. If the timer is not engaged, the unit will work continuously.

Setting the Timer to Automatically Power-On the Unit

While the machine is turned off, you can set the machine to power on by pressing the ‘Timer’ button, and setting the desired time. For example, if you set the timer to '2', the unit will automatically turn on after 2 hours.

Heating function

1.When using Heat Pump, the ambient warm air is recycled and use to heat the area where it is required. The Exhaust Pipe must be fitted firmly to allow the cold air to be removed outside.

2.Continuous drain is compulsory while the unit is in heat mode. Working range for heating function is 41 to 81oF. For temperature outside this range. the unit may not work properly.