[How to lock]
(1) Switch off the monitor’s power by the power button on the control panel.
(2) Press on the Auto adjustment button while switching on the monitor’s power.
[How to unlock]
(1) Switch off the monitor’s power by the power button on the control panel.
(2) Hold down the Auto adjustment button once again and turn the power back on.
Off Timer
The off timer function causes the monitor to automatically enter a power off state after a predetermined amount of time has lapsed. This function was created to reduce afterimage (p.49) characteristics that are particular to LCD monitors when the monitor screen is left on for a long period without use.
[Procedure]
(1) Select <Off Timer> in the ScreenManager <Others> menu.
(2) Select “Enable” and press the Right and Left Buttons to adjust the “On Period” (1 to 23 hours).
[Off Timer system]
Input Signal Selection Button
Unlocked function
Locked function
Use the “Adjustment Lock” function to prevent any accidental changes.
• Adjustments and settings in the ScreenManager.
• Auto Adjustment Button
• Selecting of the FineContrast mode by the Control Buttons.
•
English
Adjustment Lock
PC | Monitor | Power Indicator |
On Period (1H - 23H) | Operation | Blue |
Last 15 min. in "On period" | Advance Notice *1 | Blue Flashing |
|
|
|
"On period" expired | Power off | Flashing yellow slowly |
*1Advance notice (Power Indicator flashing blue) will be given 15 minutes before the monitor automatically enters the “Power Off” mode. To delay entering the “Power Off” mode, press the Power Button during the advance notice period. The monitor will continue to operate for an additional 90 minutes.
[Power Resumption Procedure]
Press the Power Button to return to a normal screen.
NOTE
•The off timer function works while the PowerManager is active, but there is no advance notice before the monitor’s power is switched off.
24 3. ScreenManager