Design Spot 1200C™
©Elation Professional® 12 Design Spot 1200C™
6. LAMP INSTALLATION INSTRUCTIONS For a proper and safe lamp change, please follow the instructions in this chapter carefully.
Safety Regulations
• To prevent accidental shock disconnect the unit’s main power supply.
• Allow the unit to cool for at least 15 minutes before attempting any type of service.
• Before you put the Design Spot 1200C™ into operation after a lamp change or
service, be sure all covers have been replaced and/or closed and secured.
Operating the fixture with the covers removed risk damage to the retina and
exposure to harmful UV radiation!
• Always replace the lamp with an approved replacement type. Always replace with a
lamp that meets the original lamp specification, failure to do so may damage the
unit and will void your manufactures warranty.
• Be sure to follow all the lamp handling procedures included with your new lamp.
Never handle the new lamp with your bare hands as the oils from your skin may
damage the lamp.
Installation Procedure:
1. Set the fixture on a flat surface and remove the four screws labeled “A” “B,” “C,” and
“D” found on the back plate of the head assembly to access the lamp.
2. Gently remove the old lamp by grasping the ceramic base and turning it
counter-clockwise until it is loose.
3. Insert the new lamp securely, locking the lamp by turning it clockwise until it locks in