10.4.2. Service Settings – These adjustments and settings should only be performed by a
technician familiar with the functionality this fixture. Incorrect setting of these
functions may result reduced performance or damage to the fixture.
Service Password: The correct password must be entered before attempting wheel
calibration, changing fan voltage, or changing the gobo speed.
Fan Voltage: This function will change the fan voltage from either “Low” or “High.”
Low will send normal voltage to the fan, for normal operation. High will send slightly
higher voltage to fans that allows the fans to operate at higher than normal speeds.
This setting should only be used in extreme cases of higher than normal
temperatures. Using the fans in “HIGH” mode will decrease fan life over time. Low is
the default setting.
Gobo Speed: This function will change the functionality of the gobo wheels. When
this function is set to “Quick” the gobo wheels will snap into position, when this
function is set to “Slow” the gobo wheels will react to position changes much slower.
“Quick” is the deg=fault setting.
10.4.3. Fans Control - This function is used to change the functionality of the internal
cooling fans. The available selections are: 1) “AUTO” – The fans will automatically
switch between low and high speeds depending on the internal operating
temperature. 2) “HIGH” – The fans will run in high-speed mode regardless of
operating temperature. 3) “LOW” – The fans will remain in low speeds regardless of
internal operating temperature.
10.4.4. Display Settings - With this function, you can set the display to turn “off” or blackout
when during normal operation. To turn the menu on momentarily, simply press any
of the menu function buttons.
10.4.5. Temperature C/F – This function changes the temperature unit readout from either
the temperature Celsius or Fahrenheit.