Design Spot 1200C™
©Elation Professional® 34 Design Spot 1200C™
11. DMX ADDRESSING
Setting the DMX address - After the fixture is turned “ON” it will immediately complete a
reset process that test all the fixture’s functions. When the reset process concludes the LCD
will display the fixture’s current DMX address. If the fixture is not receiving a DMX signal, the
display will flash continuously. To set or adjust a DMX address, please follow the procedure
below:
1. Toggle through the menu by pressing the Up and Down buttons until the display
reads “Set DMX Address.” Tap the enter button to make changes to the address.
2. While the current three-digit address is flashing use the “UP” and “DOWN”
buttons to select a new address. Once the new address has been selected, lock
the new address into the fixture’s memory by pressing the “ENTER” button.
The DMX address is non-volatile and will remain in the fixture’s memory even when the
power to the unit is switched off. Memory is backed-up and retain by an internal power
source that should last about five years
Remote DMX addressing (RDMX) / Address Via DMX- This function allows the DMX
address to be changed remotely from a DMX console. This setting requires special settings
for both the controller and the fixture. RDMX is on by default. Follow the procedure listed
below to access the RDMX functions:
Fixture Settings:
1. Access the main menu and use the UP or DOWN to get to the “Personality”
menu, then press ENTER.
2. Once in the “Personalities” menu, tap the UP or Down to get to the “Status
Settings “ menu, press ENTER.
3. Once in the “Status Settings” tap the UP or Down to get to the “Address via
DMX” function and press ENTER. “Address via DMX” is the function that
turn the RDMX function on and off.
4. Press the UP button to display “ON” to activate this function, or “OFF” to
deactivate this function.
5. Press ENTER to confirm.