Design Beam 300™
©Elation Professional, Los Angeles Ca. 11 www.ElationLighting.com
5. LAMP INSTALLATION INSTRUCTIONS
Installing or replacing the lamp
For a proper and safe lamp change, please read this chapter carefully and follow all
instructions.
Safety Regulations
Disconnect the unit’s main power supply.
Allow the unit to cool for at least 15 minutes before attempting any type of service.
Before the Design Beam 300™ is put into operation be sure all covers have been
replaced, otherwise you risk damage to the retina and expose to UV radiation!
When replacing an old lamp always be sure to replace with an approved
replacement. Be sure the replacement lamp meets or exceeds the original lamp
specifications, failure to do so may damage the fixture and void the manufactures
warranty. Be sure to follow all the lamp handling procedures included with the new
lamp. Never handle the new lamp with your bare hands as the oils from your skin
may damage the lamp and cause premature lamp failure.
Installation Procedure:
1. Set the fixture on a flat surface and turn the ¼” turn locking screw counter-clockwise
until they unsecured.
2. Flip down the lamp cover to access the lamp.