Operation

Operation

!Plug power cord into a grounded electrical outlet.

Turn power switch on rear of unit to " ON" position. Warm-up is complete when the display on control module.shows " Ready to Fog"

!To emit fog, press the appropriate button on the control module for the desired length of time.

!The control unit's display will cycle " Warming up" and " Ready to Fog " as the machine re-heats to the proper operating temperature.

!For further information on operating your ANTARI Fog Machine, see the section titled, "Contrd Module Operation".on pagexx.

If your model includes a mounting bracket designed for overhead installation, it may be installed at floor level or suspended overhead. If the unit is to be mounted using the bracket, it is important that the fog does not shoot directly at any one's face. Whatever installation method you choose, do not allow the unit to have more than a 15 degree angle of inclination.

Important:

Always monitor tank fluid level as you are fogging. Running a fog

machine with no fluid can permanently damage the unit.

If you experience low output, pump noise or no output at all, unplug immediately. Check fluid level, the external fuse,control module connection, and power from the wall. If all of the above appears to be O.K., plug the unit in again. If fog does not come out after holding the control module button down for 30 seconds, check the hose attached to the tank to make sure there is fluid