Image 9
EASY REMOTE

REAR VIEW

The STATUS LED provides optical indication of CAN-bus traffic. When the power amplifier’s address is set to “00” so that it is separated from the CAN- bus, the STATUS LED blinks every 3 seconds. When the power amplifier’s address is set between “01” and “250” and no CAN-bus activity has taken

place yet, the LED blinks every second. As soon as CAN-bus communication is recognized, the LED is activated for at least 100ms whenever the power amplifier actively sends data on the CAN-bus.

The STATUS LED may also be activated from the PC. In this case, the LED of the according power

amplifier blinks fast and steady while all other status-LEDs within the system stay dimmed

EASY REMOTE

Easy Remote provides a simple way to remotely power-on/off the power amplifier. The Easy Remote function is only useful for appliances not employing a RCM-24 Module. Controlling appliances with RCM-24 Module installed per Easy Remote is practically pointless

EASY REMOTE IN

Leaving the pins of the EASY REMOTE IN socket open, i.e. when connecting +5V, the appliance power is switched on. When connecting the EASY REMOTE IN, i.e. when feeding 0V from the control output, the appliance enters standby mode

EASY REMOTE SLAVE

The EASY REMOTE SLAVE connector provides connection for additional appliances with Easy- Remote function (e.g. for switching several devices within a rack-shelf ON/OFF).

The switching of the slave-units is delayed to prevent the mains fuses from blowing.

POWER AMPLIFIER OUTPUTS

4-pole binding-post terminals are provided for the power amplifier channels „A“ and „B“.

When connecting loudspeaker systems, please mind the polarity according to the here shown diagram.

Since the binding-post terminals might carry high voltages during operation that might cause shock-hazard, closing the attached cover is mandatory after establishing loudspeaker connections.

GROUND-LIFT SWITCH

The ground-lift switch allows eliminating noise loops. If the power amplifier is operated together with other equipment in a 19“ rack-shelf, setting the switch to its GROUNDED position is recommended. If the power amplifier is operated together with appliances with differing ground potentials, setting the switch to its UNGROUNDED position is recommended

MAINS INPUT

Under normal circumstances, the mains fuse only blows in case of fault. Replacing the fuse is only permissible when using a new fuse of the same type with identical amperage, voltage and blow characteristics. If the mains fuse blows more often, please contact an authorized service centre.

9

Page 9
Image 9
Electro-Voice P1200RL Easy Remote In, Easy Remote Slave, Power Amplifier Outputs, Ground-Liftswitch, Mains Input