Electro-Voice P900RL, P1200RL owner manual Mains Operation & Resulting Temperature

Models: P1200RL P900RL

1 36
Download 36 pages 37.86 Kb
Page 14
Image 14
MAINS OPERATION & RESULTING TEMPERATURE

MAINS OPERATION & RESULTING TEMPERATURE

MAINS OPERATION

The following tables allow determining power supply and cabling requirements. The values of the column „1/8 max. Output @ 4” are relevant for “normal” operation. These values are based on operating the power amplifier with VDE-noise at 1/8 of the maximum output power, which approximately equates the load of the power amplifier being operated with a music signal at maximum volume possible, without noticeable clipping

RESULTING TEMPERATURE INSIDE THE POWER AMPLIFIER

The power drawn from the mains network is converted into acoustic output power to feed the connected loudspeaker systems & heat. The difference between drawn power and dispensed power is called leakage power or dissipation (Pd). The amount of heat resulting from power dissipation might remain inside of a rack-shelf and needs to be diverted using appropriate measures. The following table provides auxiliary means for calculating the temperatures inside of a rack-shelf system/cabinet and the ventilation efforts necessary.

The column “Pd” lists the leakage power in relation to different operational states. The column “BTU/hr” lists the dispensed heat amount per hour

P1200RL

U Mains [V]

I Mains [A]

P Mains [W]

Pout [W]

Pd [W]

BTU/hr(3)

Idling

230V

0.55

85

 

85

290

Max. Output @ 8(1)

230V

6.40

1185

2 x 380

425

1450

Max. Output @ 4(1)

230V

10.5

2030

2 x 600

830

2832

1⁄3 max. Output @ 4(1)

230V

6.60

1230

2 x 200

830

2832

1⁄8 max. Output @ 4(2)

230V

3.80

675

2 x 75

525

1791

Normal Operation (-10dB) @ 4(1)

230V

3.78

670

2 x 50

570

1945

Nominal operation (0dB) @ 4(1)

230V

9.69

1870

2 x 500

870

2969

Alarm Operation (-3dB) @ 4(1)

230V

7.27

1370

2 x 250

870

2969

P900RL

U Mains [V]

I Mains [A]

P Mains [W]

Pout [W]

Pd [W]

BTU/hr(3)

Idling

230V

0.45

70

 

70

239

Max. Output @ 8(1)

230V

4.97

920

2 x 280

360

1228

Max. Output @ 4(1)

230V

8.16

1580

2 x 450

680

2320

1⁄3 max. Output @ 4(1)

230V

5.13

960

2 x 150

660

2252

1⁄8 max. Output @ 4(2)

230V

2.90

520

2 x 56.3

407.5

1390

Normal Operation (-10dB) @ 4(1)

230V

2.84

505

2 x 35

435

1484

Nenn Operation (0dB) @ 4(1)

230V

7.32

1410

2 x 350

710

2423

Alarm Operation (-3dB) @ 4(1)

230V

5.48

1030

2 x 175

680

2320

For approximation; when operating the appliance at 120V mains the stated current values need to be doubled.

(1)modulated with sine signal

(2)modulated with VDE-noise

(3)1BTU = 1055.06J = 1055.06Ws

14

Page 14
Image 14
Electro-Voice P900RL, P1200RL Mains Operation & Resulting Temperature, Resulting Temperature Inside The Power Amplifier