Electric Cooktop Installation Over
30" Single Electric Wall Oven
For all approved electric cooktop models, cut minimum 4" x 4" opening in right cabinet side panel and/or filler panel, to route armoured cable to junction box
Side filler panels necessary to isolate oven from | 240 /208V | |
adjoining cabinets. Panel height may need to | ||
Junction box | ||
be modified to accommodate the depth of approved | ||
for electric | ||
electric cooktop models | ||
cooktop | ||
| ||
Cooktop | Approx. 3" | |
cutout** | ||
| ||
| Oven cutout | |
| 36" | |
| min. | |
Approx. 3" | 28 1/4" min. | |
24" min.* | 28 7/8" max. | |
240 /208V |
| |
Junction box | 28 1/2" min. | |
for wall oven | 29" max. | |
| ||
24" min. | Install 3/4" full plywood base on 2 runners, flush | |
cutout depth | with toe plate, capable of supporting 200 lbs. |
Unit will overlap cutout (minimum) edges by 1"
To route armoured cable to junction box through left cabinet side panel and/or filler panel, cut minimum 4" x 4" opening in wood base and runner
*Critical dimension – MUST be applied **For cooktop cutout dimensions refer to
Electric Cooktop Installation Over
30" Single Electric Wall Oven Specifications
Single Wall Ovens are approved to be used beneath Electrolux ICON™ electric cooktop models E36IC75FSS, E30IC75FSS, E36EC70FSS and E30EC70FSS (electric cooktop models NOT approved for use in this installation are E36EC75ESS, E30EC65ESS and E36EC65ESS.
For detailed Electric Cooktop installation specifications, refer to
•Side filler panels necessary to isolate oven from adjoining cabinets. Panel height may need to be modified to accommodate the depth of approved electric cooktop models.
•To route armoured cable to junction box, cut minimum 4" x 4" opening in right cabinet side panel.
•Allow
30" Single Electric Wall Oven
•Product Weights –
(E30EW75EPS) 177 Lbs. / (E30EW75ESS) 168 Lbs.
•Single phase 3- or
•Connected Load (kW Rating) – 240 / 208 Volts = 4.0 / 3.0 kW
•Amps @ 240 / 208 Volts = 16.6 / 14.4 Amps
•Always consult local and /or national electric codes.
•Minimum
•Minimum 24" deep, cutout dimension is critical for proper install- ation. If oven’s face profile does not fit flush against cabinet, or if noise is heard from oven’s convection system, verify dimension.
•Full oven base of solid plywood or similar material required, capable of supporting 200 Lbs. Install over two runners and flush with toe plate.
•Base must be level and cabinet front must be square.
•Side filler panels necessary to isolate oven from adjoining cabinets.
•Allow 5" maximum height from oven base to floor, if NO cooktop is installed directly over wall oven.
Note: Refer to Product Installation Guides for detailed instructions on the web at electroluxusa.com.