Part Names and Functions

Camera Initial Settings

Setting Communications Protocol

Use the SW2 #1~#5 of installation bracket to set the communications protocol.

Rear panel Number

Protocol

Baud Rate(BPS)

SW2-#1

SW2-#2

SW2-#3

SW2-#4

SW2-#5

Samsung

9,600

OFF

OFF

OFF

OFF

OFF

Samsung

19,200

OFF

OFF

OFF

OFF

ON

Pelco-D

2,400

OFF

OFF

OFF

ON

OFF

Pelco-D

4,800

OFF

OFF

OFF

ON

ON

Pelco-P

4,800

OFF

OFF

ON

OFF

OFF

Pelco-P

9,600

OFF

OFF

ON

OFF

ON

Samsung Elec.

9,600

OFF

OFF

ON

ON

OFF

Samsung Elec.

19,200

OFF

OFF

ON

ON

ON

Panasonic

9,600

OFF

ON

OFF

OFF

OFF

Panasonic

19,200

OFF

ON

OFF

OFF

ON

Vicon

4,800

OFF

ON

OFF

ON

OFF

Vicon

9,600

OFF

ON

OFF

ON

ON

AD

4,800

OFF

ON

ON

OFF

OFF

Bosch

9,600

OFF

ON

ON

OFF

ON

Bosch

19,200

OFF

ON

ON

ON

OFF

Honeywell

9,600

OFF

ON

ON

ON

ON

Honeywell

19,200

ON

OFF

OFF

OFF

OFF

SUNGJIN

4,800

ON

OFF

OFF

OFF

ON

Pelco-D

9,600

ON

OFF

OFF

ON

OFF

Reserved

 

 

 

 

 

 

Notes

Default Setting : Samsung 9,600 bps

When you set up, refer to rear panel number(Ignore, DIP SWITCH number).

Please see our homepage for details on the protocol

Setting Baud Rate Based on DVR Model

If the speed dome camera is controlled not by the camera controller but by a DVR, set the communication speed based on the DVR model as follows.

Protocol

Samsung

Pelco

Samsung Elec.

DVR Model

 

 

 

SVR-950

9600,19200

2400,4800

19,200

SVR-1640

9600,19200

2400,4800

19,200

SVR-1650

9600,19200

2400,4800

19,200

Setting Transmission Mode

Set the transmission mode using the ON/OFF of the Rear Panel SW2.

Rear panel Number

 

Function

ON

OFF

SW2- #6

Transmission Mode

Full

Half

 

Selection

(DVR)

(SCC-3100A)

Notes

Factory Setting: OFF

When you set up, refer to rear panel number(Ignore, DIP SWITCH number).

12

13

Page 7
Image 7
Samsung SPD-1000 user manual Camera Initial Settings, Setting Baud Rate Based on DVR Model