Functional Description
PTZ Trace : Maximum 4 patterns of the manual operation paths (for Pan, Tilt, Zoom and Focus) are memorized and replayed.
Sequence Setting | PTZ Trace | |
Preset | Trace | 1 |
Swing SEQ | Trace | 2 |
Group SEQ | Trace | 3 |
Tour SEQ | Trace | 4 |
PTZ Trace |
|
|
Auto Run |
|
|
Power On Resume OFF |
|
|
Replay : The manual operation paths are repeated and replayed. Stop key will stop the replay.
* If the operation range is limited using | Pan Limit and | Tilt Limit, please note that other operations |
beyond the limited operation range are not possible. |
|
Memorize: Manual operations for minimum 120 seconds after executing this function are memorized into the internal memory. Nevertheless, the memorizing time becomes different depending on the PTZ operation. OVER mark will finish this function.
*If the operation range is limited using Pan Limit and Tilt Limit, only the operations within the limited range are memorized.
Notes
• Press the OSD key to stop the internal memory to continue saving.
Auto Run: If there is no controller operation by the user for a certain time, the sequence operation designated by the user will be executed.
Mode - • OFF : Auto Run will be cancelled.
•Preset : Auto Run in the corresponding Preset number
•Swing : Auto Run in the corresponding Swing mode
•Group : Auto Run in the corresponding Group number
• Tour | : Auto Run in the corresponding Tour number |
• Trace | : Auto Run in the corresponding Trace number |
•A. Pan : 350˚ Auto Run in Pan direction
*Auto Pan Speed: Pan operation in the speed designated by the user
*Tilt Angle: The tilt angle set up by the user is kept.
Time : Auto Run operation is executed after a certain time designated by the user.
* Time can be set up by the unit of 1-59 SEC and 1-59 MIN
Power On Resume : When the power supply for the camera is stopped for some reason, such as electricity failure, and resumed, the Sequence Settings before the power off are restored.
Sequence Setting | Sequence Setting |
Preset | Preset |
Swing SEQ | Swing SEQ |
Group SEQ | Group SEQ |
Tour SEQ | Tour SEQ |
PTZ Trace | PTZ Trace |
Auto Run | Auto Run |
Power On Resume OFF | Power On Resume ON |
3) P/T Setting
Pan Limit : The moving range in the Pan direction can be limited.
Main Menu | P/T Setting |
|
Camera Setting | Pan Limit |
|
Sequence Setting | Tilt Limit |
|
P/T Setting | Area Setting |
|
OSD Setting | Area Masking |
|
Alarm Setting | Prop. P/T | ON |
Initialize | Digital Flip | ON |
Status | Jog Speed | Manual |
Position : Moving range can be set up. Set the position from the left using the joystick and the Execution key. The stop position may change due to the initialization by such operation as power resumption depending on position setting. This does not mean it is out of order.
On/Off : When this function is on, the limit is effective. Default setting is Off.
46 | 47 |