Gas Cooktop Installation Over
30" Single Electric Wall Oven
For all approved gas cooktop models, a minimum | 120V/60Hz | Cooktop |
|
| 18" max. |
| Countertop |
|
|
|
|
|
| ||
height opening of | grounded |
| 1 |
|
| 4" |
|
in right cabinet side panel and/or filler panel, to route | outlet, for | Manifold | 2 | 5" | Gas | ||
6 / " |
| ||||||
gas and electric hookups. (Refer to Gas Cooktop | gas cooktop | pipe | min. |
|
| Cooktop | |
Utility Hookup Diagram) |
| Flare union |
|
|
|
| Utility |
|
|
|
|
|
| Hookup | |
|
| Flexible connector |
|
|
|
| |
Side filler panels necessary to isolate oven from |
|
|
|
| Flare |
| |
adjoining cabinets. Panel height may need to |
|
|
|
|
|
| |
| Pressure regulator |
|
|
| union | 120V/60Hz | |
be modified to accommodate the depth of approved |
|
|
|
| |||
|
|
|
|
| grounded outlet | ||
gas cooktop models |
|
|
|
|
|
| |
| Cabinet sides |
|
|
|
|
| |
|
|
|
| Manual shutoff valve | |||
|
| and/or filler panel |
|
| (Must be accessible) |
| |
Cooktop |
|
|
|
|
|
| Side View |
cutout** |
|
|
|
|
|
| |
|
| Oven cutout |
|
| 36" |
| Cooktop |
|
|
|
|
|
| ||
|
|
|
| min. |
|
| |
Approx. 3" |
| 28 1/4" min. |
|
|
|
|
|
24" min.* |
| 28 7/8" max. |
|
|
|
|
|
240 /208V |
|
|
|
|
|
| Wall Oven |
Junction box | 28 1/2" min. |
|
|
|
|
|
|
for wall oven | 29" max. |
|
|
|
|
|
|
|
|
|
|
|
|
| |
24" min. | Install 3/4" full plywood base on 2 runners, flush |
|
| ||||
cutout depth | with toe plate, capable of supporting 200 lbs. |
|
|
Unit will overlap cutout (minimum) edges by 1"
To route armoured cable to junction box through left cabinet side panel and/or filler panel, cut minimum 4" x 4" opening in wood base and runner
*Critical dimension – MUST be applied **For cooktop cutout dimensions refer to
Gas Cooktop Installation Over
30" Single Electric Wall Oven Specifications
Single Wall Ovens are approved to be used beneath Electrolux ICON™ gas cooktop models E46GC66ESS, E36GC65ESS, E36GC70FSS and E30GC70FSS (gas cooktop models NOT approved for use in this installation are E36GC75ESS, E46GC67ESS, E36GC76EPS, E48GC76EPS and E30GC64ESS.)
For detailed Gas Cooktop installation specifications, refer to
•Side filler panels necessary to isolate oven from adjoining cabinets. Panel height may need to be modified to accommodate the depth of approved gas cooktop models.
•Minimum height opening of
•Allow
30" Single Electric Wall Oven
•Product Weights –
(E30EW75EPS) 177 Lbs. / (E30EW75ESS) 168 Lbs.
•Single phase 3- or
•Connected Load (kW Rating) – 240 / 208 Volts = 4.0 / 3.0 kW
•Amps @ 240 / 208 Volts = 16.6 / 14.4 Amps
•Always consult local and /or national electric codes.
•Minimum
•Minimum 24" deep, cutout dimension is critical for proper install- ation. If oven’s face profile does not fit flush against cabinet, or if noise is heard from oven’s convection system, verify dimension.
•Full oven base of solid plywood or similar material required, capable of supporting 200 Lbs. Install over two runners and flush with toe plate.
•Base must be level and cabinet front must be square.
•Side filler panels necessary to isolate oven from adjoining cabinets.
•Allow 5" maximum height from oven base to floor, if NO cooktop is installed directly over wall oven.
Note: Refer to Product Installation Guides for detailed instructions on the web at electroluxusa.com.