Cleaning the fine strainer
The fine strainer must be cleaned from time to time:
-Unlock the strainer by turning it to position A, lift out the fine strainer and clean it under running wa ter with a brush.
-Place the strainer in its holder and secure it by tur ning to position B.
Cleaning the spray arm nozz les
Regularly check the nozzles on the three spray arms for blockages. If necessary, clean out the nozzles with a fine wire or a fine pin and a strong jet of water.
Take care not damage the nozzle openings.
Roof spray arm
Remove the roof spray arm:
-Loosen the securing screw (A) by turning to the left.
-Pull the spray arm from the shaft.
-Clean the spray arm and the securing screw.
-Refix the spray arm with the securing screw (A) by turning to the right.
Central spray arm
-Remove the central spray arm by turning it to the side, and hoisting off.
The
-To
Lower spray arm
Remove the lower spray arm:
-Loosen the nut (C) by turning it to the left
-Pull the spray arm from the shaft
-Clean the nozzles
-Refix the spray arm with the nut (C) by turning to the right.
A
B
A
B
C
19