Electrolux 5995421640 manual Sample Area

Models: 5995421640

1 33
Download 33 pages 20.56 Kb
Page 24
Image 24

24Operation

3Locate the ice cube thickness adjustment dial on the control board (see Figure 30). Turn the dial clockwise (+ number) or counterclockwise

(- number) to thin the ice bridge.

Figure 30

 

 

 

DIAL IS

 

 

 

FACTORY

 

 

 

SET AT “0”

 

 

 

2

3

4

5

 

 

 

1

 

 

 

0

 

 

 

-1

 

 

 

-2

-3

-4

-5

 

 

 

ICE CUBE THICKNESS

 

 

 

ADJUSTMENT DIAL

IMPORTANT

Ice thickness adjustment dial can be rotated 1/4 to 1/2 turn on the number dial. Allow the ice maker to stabilize for 24 hours before making further adjustments. Since ice cubes in any given batch will vary, choose cubes from the sample area for comparison when making adjustments (see Figure 31). The factory setting is 0.

Ice Cube Mold

SAMPLE AREA

4Reinstall the front access cover.

5Reconnect power to icemaker.

Figure 31

ICE005