DOC. NO. 5956.677.00 P. 2 9 / 3 0

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

* If the value of the parameter "Heat tim. enable" (HtE) is "Yes" (1), the machine stops when this alarm

appears. If the parameter value is "No" (0), the machine does not shut down when this alarm appears.

** The machine does not shut down if these alarms appear. Every 8 seconds a message indicating the

alarm number is shown on the display. A red LED blinks, but the machine continues to carry out the normal

operations.

*** This alarm causes machine stop in versions without prewash. In prewash versions the machine continues

to work.

76 The gear motor supplied current is
higher than the maximum value
allowed for the gear motor current.
- The wire connected from the inverter ( Do terminal block) to the elctronic board (X7-5) is short-
circuited with the ground.
- The inverter parameters are not correctly set.
77 The gear motor supplied current is
lower than the minimum value
allowed for the gear motor current.
- The wire connected from the inverter ( Do terminal block) to the electronic board (X7-5) is open.
- The inverter parameters are not correctly set.
- The gear motor is configured with star connection and it must be configured with delta
connections.
89 The temperature on the user
interface is too high. - Presence of steam too hot on the user interface board.
- The user interface doesn’t work properly.
101 ** The power absorbed by the boiler
heating elements is less than the
foreseen rated power.
- One or more branches of the boiler heating elements are disconnected.
- One or more remote control switches that control the boiler heating elements do not work
properly.
- The relay of the MEC board that supplies the boiler heating element remote control switch coils
does not work properly.
- The connection wiring between the remote control switches and the boiler heating elements or
between the MEC board and the boiler heating element remote control switch coils is
disconnected.
- The parameter Pulse/KWatt Hour (EnP) is not correctly set.
- The energy meter connections are not correct.
102 ** The power absorbed by the wash
tank heating elements is lower than
the foreseen rated power.
- One or more branches of the boiler heating elements are disconnected.
- One or more remote control switches that control the wash tank heating elements do not work
properly.
- The relay of the MEC board that supplies the wash tank heating element remote control switch
coils does not work properly.
- The connection wiring between the remote control switches and the boiler heating elements or
between the MEC board and the wash tank heating element remote control switch coils is
disconnected.
- The parameter Pulse/KWatt Hour (EnP) is not correctly set.
- The energy meter connections are not correct.
103 ** The power absorbed by the prewash
tank heating elements is lower than
the foreseen rated power.
- One or more branches of the boiler heating elements are disconnected.
- One or more remote control switches that control the prewash tank heating elements do not work
properly.
- The relay of the MEC board that supplies the prewash tank heating element remote control switch
coils does not work properly.
- The connection wiring between the remote control switches and the prewash tank heating
elements or between the MEC board and the prewash tank heating element remote control switch
coils is disconnected.
- The parameter Pulse/KWatt Hour (EnP) is not correctly set.
- The energy meterconnections are not correct.

CoM

Err

(compact
machines)
Communication problems between
machine electronic boards. - The bus connection cables are not correctly connected to all the boards.
- One or more boards don’t work properly.
- The “Appl. type” parameter (APt) is not correctly set.
- Connector X6 is not correctly inserted in the MEC boards.
When alarm COM Err appears, the display will show the number of the electronic board that
generated the communication error.
2: wash + rinse
3: prewash
If, after a communication error, the machine is able to re-enable the communication between the
boards, the following message appears on the display:
NoCoMErr