Installation
10
Electrical Connection
Any electrical work required to install this appliance should be carried
out by a qualified electrician or competent person.
WARNING – THIS APPLIANCE MUST BE EARTHED
The manufacturer declines any liability should these safety mea-
sures not be observed.
Before switching on, make sure the electricity supply voltage is the
same as that indicated on the appliance rating plate. The rating plate
is inside, on the left.
The appliance is supplied with a 13 amp plug fitted. In the event of
having to change the fuse in the plug sup-
plied, a 13 amp ASTA approved (BS 1362)
fuse must be used.
Important
The wires in the mains lead are coloured in
accordance with the
following code:
Green and Yellow Earth
Blue Neutral
Brown Live
As the colours of the wires in the mains lead of this appliance may not
correspond with
the coloured markings identifying the terminals in your plug, proceed
as follows:
1.The wire coloured green and yellow must be connected to the termi-
nal marked with the letter “E” or by the earth symbol or coloured
green and yellow.
2.The wire coloured blue must be connected to the terminal marked
“N” or coloured black.
3.The wire coloured brown must be connected to the terminal marked
“L” or coloured red.
4.Upon completion there must be no cut, or stray strands of wire pre-
sent and the cord clamp must be secure over the outer sheath.
Warning! A cut-off plug inserted into a 13 amp socket is a serious
safety (shock) hazard. Ensure that the cut-off plug is disposed of
safely.
D207
GREEN & YELLOW 13 AMP. FUSE
BROWN
CORD CLAMP
BLUE
13 AMP